1-100 (No.RA053<Rev.001>)
7. NXDN
High
Deviation
[NXDN
Narrow]
1) Adj item:
[Nn NDEV]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[L5]
→
[C1]
→
[C3 TxOL:L]
→
[C5]
→
[H2]
→
[H4]
→
[H6]
→
[C3 TxOL:H
(Long press the
[
] button)]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[NXDN High
Deviation (NXDN
Narrow]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
→
[Overlap]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write fixed value “500”
for each adjustment
point.
Transmit at each
adjustment point and
check that the Analog
deviation is between
2995Hz and 3117Hz.
Deviation meter
LPF: 3kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
2995~3117Hz
[NXDN
Very
Narrow]
1) Adj item:
[Nv NDEV]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[L5]
→
[C1]
→
[C3 TxOL:L]
→
[C5]
→
[H2]
→
[H4]
→
[H6]
→
[C3 TxOL:H
(Long press the
[
] button)]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[NXDN High
Deviation (NXDN
Very Narrow]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Low5]
→
[Center1]
→
[Center3]
→
[Center5]
→
[High2]
→
[High4]
→
[High6]
→
[Overlap]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write fixed value “500”
for each adjustment
point. Transmit at each
adjustment point and
check that the Analog
deviation is between
1311Hz and 1363Hz.
Deviation meter
LPF: 3kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
1311~1363Hz
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
Panel tuning
mode
PC test mode
Test-
equipment
Unit Terminal Unit
Parts
Method