(No.RA053<Rev.001>)1-49
14. MSK
Deviation
[Analog
Wide]
1) Adj item:
[Aw MSK]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[MSK Deviation
(Analog Wide)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write the value as
followings.
505 (Reference value)
3.00kHz±0.05
kHz
[Analog
Narrow]
1) Adj item:
[An MSK]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[MSK Deviation
(Analog Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write the value as
followings.
505 (Reference value)
1.50kHz±0.05
kHz
15.
CWID
Deviation
[Analog
Narrow]
1) Adj item:
[An CWID]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[CWID Deviation
(Analog Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write the value as
followings.
511 (Reference value)
1.10kHz±0.10
kHz
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
Panel tuning
mode
PC test mode
Test-
equipment
Unit Terminal Unit
Parts
Method