1-38 (No.RA053<Rev.001>)
4.4
Adjustment points
TX-RX UNIT (XC1-178)
Component Side
4.5
Test Equipment Required for Alignment
* The test equipment which is not used for adjustment is contained in this table.
RTC (CN412)
Test Equipment
Major Specifications
1. Standard Signal
Generator (SSG)
Frequency Range
Modulation
Output
100 to 900MHz
Frequency modulation and external modulation
-127dBm/0.1uV to greater than -20dBm/22.4mV
When performing the Frequency adjustment, the following accuracy is necessary.
• 0.003ppm
Use a standard oscillator for adjustments, if necessary.
2. Power Meter
Input Impedance
Operation Frequency
Measurement Capability
50ohm
100 to 900MHz
Vicinity of 10W
3. Deviation Meter
Frequency Range
100 to 900MHz
4. Digital Volt Meter
(DVM)
Measuring Range
Input Impedance
10mV to 10V DC
High input impedance for minimum circuit loading
5. Oscilloscope
DC through 30MHz
6. Frequency Counter
Frequency Range
Frequency Stability
10Hz to 1000MHz
0.2ppm or less
To measure the oscillating frequency of the internal clock 32766.00Hz~32770.00Hz for
RTC Correction Resolution 0.01Hz is better for accuracy adjustment.
7. Ammeter
5A
8. AF Volt Meter (AF VM)
Frequency Range
Voltage Range
50Hz to 10kHz
1mV to 10V
9. Audio Generator (AG)
Frequency Range
Output
50Hz to 5kHz or more
0 to 1V
10. Distortion Meter
Capability
Input Level
3% or less at 1kHz
50mV to 10Vrms
11. Spectrum Analyzer
Measuring Range
DC to 1GHz or more
12. 8ohm Dummy Load
Approx. 8ohm, 3W
13. Regulated Power Supply
5V to 10V, approx. 3A, Useful if ammeter equipped