ADJUSTMENT
Test Equipment Required for Alignment
Test Equipment
Major Specifi cations
1. Standard Signal Generator
(SSG)
Frequency Range
800 to 950MHz
Modulation
Frequency modulation and external modulation
Output
0.1µV to greater than 1mV
2. RF Power Meter
Input Impedance
50
Operation Frequency
800 to 950MHz
Measurement Capability
25mW to 2.5W
3. Deviation Meter
Frequency Range
800 to 950MHz
4. Digital Volt Meter (DVM)
Measuring Range
1V to 20V DC
Input Impedance
High input impedance for minimum circuit loading
5. Oscilloscope
DC through 30MHz
6. High Sensitivity
Frequency
Counter
Frequency Range
10Hz to 1000MHz
Frequency Stability
0.01ppm or less
7. DC Ammeter
15A or more
8. AF Volt Meter (AF VM)
Frequency Range
50Hz to 10kHz
Voltage Range
3mV to 3V
9. Audio Generator (AG)
Frequency Range
50Hz to 5kHz
Output
0 to 1V
10. Distortion Meter
Capability
1% or less at 1kHz
Input Level
50mV to 10Vrms
11. Voltmeter
Measuring Rnage
10V to 1.5V DC or less
Input Impedance
50k
/V or greater
12. 4
Dummy Load
Approx. 4
, 5W
13. Spectrum Analyzer
Frequency Range
1MHz to 950MHz
Input Level
Up to +20dBm
Input Sensitivity
–100dBm
Resolution Bandwidth
100Hz
Video Bandwidth
100Hz
14. Tracking Generator
Frequency Range
1MHz to 950MHz
Output Level
–30dBm to 0dBm
8
1
Cut
HOOK
(GRY)
MIC (WHT)
MICG (SHIELD)
to
AG
AF VM
PTT
(BLU)
GND
(BLK)
PTT SW
Plug cord
Part No. E30-3360-28
8 pin
8 pin
MIC connector (Front panel view)
Jig for MCF adjustment (W05-1000-00)
Jig for Drive AMP adjustment and RF AGC adjust-
ment (E30-3228-15 or E37-1304-05)
Test cable for microphone input (E30-3360-28)
1: NC
2: SB
3: GND
4: PTT
5: MIG
6: MIC
7: HOOK
8: NC