KENT INDUSTRIAL (USA) INC.
1231 Edinger ave.,Tustin,CA.92780 U.S.A.
Tel
:
(714)258-8526 Fax : (714)258-8530
3 - 5
3-4.
Electricity Requirement:
1. Power supply system:
(1) Voltage: 220V.
(2) 3 phase power supply: 60 Hz
(3) Electricity currency: over 50 Amp.
2. The diameter of power supply’s wire should be 16 to 25 mm, and mount with a
50A’s breaker (NFB breaker).
3. After inspecting the wiring and connection, please check the voltage that is 220
V
±
10%.
4. Confirm the orientation of the motor’s phase when running.
5. Compressor’s specification:
Pressure: 6 to 8 KgF / cm
Supply capacity: 200 L / min
3-5.
Remove the shipping bracket:
1. Jog the Z-axis 3 mm toward to the +Z direction, and remove the wood block (A)
between spindle and column.
2. Jog the Z-axis toward to the -Z direction in order to pull tight the chains where
upon the counterweight (B), and take out the fixed rod of the counterweight.
3. When the machine is fixed on the ground, please store the shipping bracket
well.
4. Remove all the driers hanging in the machine including electric cabinet.
5. Please DO NOT power on the machine before the shipping bracket is removed
exactly.
(A)
(B)
Property of Kent Industrial USA
Do Not Reproduce