8-1-11 TEST Mode
1. The Test mode allows checking the PCB and the function of the product as well as finding out the defective part in case of
an error.
2. The test mode is operated by pressing two buttons on the Display panel.
3. While in the test mode, the function control button is not recognized, but the recognition tone (beep~) sounds.
4. After exiting the test mode, be sure to reset by unplugging and then plugging in the appliance.
5. If an error, such as a sensor failure, is detected while in the test mode, the test mode is cleared and the error code is
displayed.
6. While an error code is displayed, the test mode will not be activated.
MODE
OPERATION
CONTENTS
REMARKS
TEST1
TEST2
Return
Push ULTRA ICE &
COLDER (F) KEYS for 3sec.
Or Push TEST switch
(on the main Board) once.
<Cooling MODE>
Push ULTRA ICE &
COLDER (F) KEY for 3sec.
In TEST MODE or Push
TEST switch once in TEST
MODE 1
On TEST 2 press
ULTRA ICE & COLDER (F)
KEY for 3 sec.
1. Continuous operation of the
COMPRESSOR
2. Continuous operation of the freezer fan
3. STEPPING DAMPER OPEN
4. Defrosting Heater OFF
5. Every DISPLAY LED ON
1. COMP OFF
2. Freezer FAN OFF
3. STEPPING DAMPER CLOSE
4. Defrosting heater ON
5. Display LED shows 222
Return to initial status (COMP 7 min delay)
Maximum test time:
2 hours.
Reset if the temperature
Maximum test time:
5 minutes
<Forced desfrosting MODE>
Of the defrosting sensor
Is 8°C (46°F) or more.
to Normal
* Freezer Fan RPM Variable Check:
If the freezer fan is in operation when the COLD REFRIGERATOR TEMP KEY & COLD FREEZER TEMP KEY are pressed
for more than one second at the same time then the freezer fan RPM changes, (for example if high speed, to normal speed or
if normal speed, to high speed for 30 seconds)
After 30 seconds, it turns to its original RPM.
* Demonstration (Display) MODE:
1. To enter this mode, raise either the Refrigerator or Freezer temperature to its highest setting. Then, press that
Cold key and hold for about 5 seconds..
2. The LED panels will display OFF, to indicate that the compressor, circulating fan , damper, and defrost heater are not
operating.
3. The Open Door Alarm and the Lamp Auto-Off feature will work normally and can be demonstrated.
4. To reset to normal operation, press and hold either Cold Key for about 5 seconds.