Symptom
Check Point
1. Er IS
1. Check for a loose connection
2. Check Sensor Resistance
Resistance [Ω]
CON9
1
st
pin ~ 8
th
pin
Short
0
Open
OFF
Other
Normal
2-3. Icing Sensor Error (Er IS)
CON9
1
st
pin ~ 8
th
pin
Resistance [Ω]
-22ºF / -30ºC
40k
-13ºF / -25ºC
30k
-4ºF / -20ºC
23k
-13ºF / -25ºC
17k
14ºF / -10ºC
13k
23ºF / -5ºC
10k
32ºF / 0ºC
8k
CON9
Ice Maker Connector
65