12-2 CHECK B
B1. LED Blinks once, then repeats. (FCT0 Fault: A-inverter)
12-2 CHECK B
B2. LED Blink two times, then repeats (Stroke Trip)
- Purpose: Detecting motor current and voltage error.
- Check voltage at
(motor voltage),
(motor current)
and
(capacitor voltage) when compressor is off.
Spec:
point A
point B
point C
Points A, B & C 2.5V ± 0.3V
- Purpose:
.
- Case 1
If compressor doesn’t work and LED blinks
Cause: Possibility harness from compressor to PCB might be defective.
-Case 2
If compressor works intermittently and LED blinks
Cause: Condenser fan or freezer fan is not running. Sealed system problem such as moisture restriction, restriction at capillary
tube or refrigerant leak.
Logic: Compressor is forced to off and then tries to restart after 1 minute.
Prevent abnormally long piston strokes
Blink
OFF Blink OFF
Y
N
Replace Driver PCB
Protection Logic
GND
Voltage
Protection
logic
Check B
Blink time 1
(FCT 0) Check B1
Blink time 1
(FCT 0) Check B1
Reset Power
Out of spec?
(2.2 - 2.8V)
Y
Y
Y
N
N
Fix harness
N
PCB
Y
Y
N
Y
N
OK
NG
Protection
logic
Check B
Replace
driver
Fix
cycle
Cycle
Check E
Repeat check
procedure
Stroke Trip
occur?
Reset
power
Compressor
works intermittently
Check
connections
Check C
Capacitor
Spec.
Check C
Compressor
damage
Check C
Replace
capacitor
Replace
compressor
Blinks 2 times
(Stroke Trip) Check B
Compressor
doesn’t work
Caution: Devices should not be short - circuited during check C
Blink
Blink
OFF
OFF
Blink
Blink
GND
C
A
B
117