1. TroubleShooting
CLAIMS.
CAUSES AND CHECK POINTS.
HOW TO CHECK
1. Faulty start
1) No power at outlet.
2) No power on cord.
3) Shorted start circuit.
4) During defrost.
* Measuring instrument:
Multi tester
Check the voltage.
If the voltage is within ±85%
of the rated voltage, it is OK.
Check the terminal
movement.
Check both terminals of
power cord.
Power conducts:OK.
No power conducts:NG
Check rating of OLP
Temp. 140°C
If rating different: change it
If not: OK
Bad connection between adapter and outlet. (faulty adapter)
The Inner diameter of adapter.
The distance between holes.
The distance between terminals.
The thickness of terminal.
Bad connection between plug and adapter (faulty plug).
The distance between pins.
Pin outer diameter.
No power on
power cord.
PTC is off.
No electric power on compressor. - Faulty compressor.
Faulty OLP
Disconnected copper wire.
Internal electrical short.
Faulty terminal contact.
Disconnected.
Capacity of PTC is small.
Characteristics of PTC is wrong.
Bad connection.
Weak connection.
Short inserted cord length.
Worn out tool blade.
Loose contact.
- Large distance between
male terminal.
- Thin female terminal.
Terminal disconnected.
Bad sleeve assembly.
Power cord is disconnected.
Faulty soldering.
Start automatic defrost.
Cycle was set at defrost when the refrigerator
was produced.
Power does not conduct. - Damage.
Characteristics of OLP is wrong
Bad connection with
compressor.
Bad terminal connection.
Too loose.
Assembly is not possible.