Symptom
Check Point
1. Er R2
1. Check for a loose connection
2. Check Sensor Resistance
Resistance [Ω]
CON6
7
th
pin ~ 8
th
pin
Short
0
Open
OFF
Other
Normal
2-2. Refrigerator Sensor Error (Er r2)
CON6
7
th
pin ~ 8
th
pin
Resistance [Ω]
23ºF / -5ºC
38k
32ºF / 0ºC
30k
41ºF / 5ºC
24k
50ºF / 10ºC
19.5k
59ºF / 15ºC
16k
CON6
61