* Driver PCB located in machine room.
Step 1. Open PCB Cover
Step 2. Check Driver PCB
?
?
Dear is PC board located in the PCB case.
The control driver is PC board for the compressor.
This step shows the source voltage of the driver PC board.
?
12-1 Check A
Multi
Tester
Check to make sure compressor is receiving voltage from IPM
- In order to determine whether the compressor is operating normally,
check the output voltage during the refrigeration cycle.
- After initial power-up, when the compressor begins too operate, wait
10 minutes before checking.
- The compressor is operating normally if the voltage is greater than
80V.
Measure the voltage between the POWER and COMM pins of the connector as shown below.
IPM Output check
116