3.2 Maintenance and inspection intervals
The company/user must ensure that repair work on and tests for breathing apparatuses are
completed in accordance with this user information (operating instructions) (see also BGR 190,
Use of Breathing Apparatuses).
Type of Tasks
to be completed
Before
Use
After
Use
semi-
annually
Welding
protection
Cleaning
Yes
(recommendation,
depending on the
level of contamination)
Yes
Disinfection
Yes
(recommendation, for
hygienic reasons)
Yes
Visual inspection for
damage
Yes
Yes
Blower unit
including
components
Cleaning
Yes
(recommendation,
depending on the
level of
contamination)
Yes
Visual inspection for
damage
Yes
Yes
Functional test
Yes
Yes
Also observe the instructions in Section 2.2 „Inspections Before Use“.The particle filter may
not be used once the maximum storage time has been exceeded (see Section 1.3 „Labelling“)!