Adjust the Cleaners on the Feeder House
Drums
To prevent stoppages in the intake channel, the distance
between cleaner (A) and guide plate (B) must not exceed
0.5 mm. If necessary, adjust cleaners (A) in the direction
shown by the arrow.
Specification
Cleaners (A) and Guide
Plate (B)—Distance from
Each Other................................................................................... 0.5 mm
0.02 in.
IMPORTANT: Two cleaners must be adjusted on
each feeder house drum.
KM285516
—UN—21NOV16
A—Cleaner
B—Guide Plate
Check Steering Sensor Voltage Readings (Rotary Harvesting Units for CLAAS forage
harvesters)
KM210174
—UN—31MAR14
A—Feeler
The following voltage values must be reached when the
feeler (A) is deflected:
•
With feeler (A) in straight position: 0,5 volts (+/- 10%)
•
With maximum deflection of feeler (A): 4.5 volts (+/- 5%)