K°Bloc – Fully welded plate heat exchangers - English Version 2.2 - 01.2016
98
7.9.2
CLEANING PLATES WITH "DOUBLE DIMPLE" PATTERN
Requirement:
The K°Bloc was opened, see chapter „7.1 Opening the K°Bloc“
(page 67).
IMPORTANT NOTE
Danger of material damage on the K°Bloc from hard
cleaning tools!
Hard cleaning tools (e.g. metal brushes) damage the metal surfaces. This
may cause corrosion.
Never use hard cleaning tools.
Work carefully and thoroughly when cleaning.
WARNING
Danger of injury due to aggressive cleaning media!
When using aggressive cleaning media, you may suffer from intoxication,
chemical burns and burns.
Wear your personal protective equipment.
Make yourself familiar with the handling of aggressive cleaning agents.
Ensure that the cleaning medium you use is completely removed from
the plate pack after the cleaning process is complete.
Carry out the following steps:
Clean the plate pack with a high-pressure jet cleaner.
Done.