K°Bloc – Fully welded plate heat exchangers - English Version 2.2 - 01.2016
92
4.
Tighten the nuts framed in Figure 7.4.2.3.b and Figure 7.4.2.3.c on the
two adjoining panels "II" and "III" to a gap size of 4 mm.
!
When tightening, proceed alternately from the centre of the line of bolts
framed in red of the adjoining panel "II" towards the outside.
!
When tightening, proceed alternately from the centre of the line of bolts
framed in red of the adjoining panel "III" towards the outside.
5.
Tighten all nuts of panel "I" (see Figure 7.4.2.3.a) crosswise to a 5 mm
gap according to the figure below (here: 1 to 22).
6.
Tighten the nuts framed in Figure 7.4.2.3.b and Figure 7.4.2.3.c on the
two adjoining panels "II" and "III" to a gap size of 3 mm.
!
When tightening, proceed alternately from the centre of the line of bolts
framed in red of the adjoining panel "II" towards the outside.
!
When tightening, proceed alternately from the centre of the line of bolts
framed in red of the adjoining panel "III" towards the outside.
7.
Tighten all nuts of panel "I" (see Figure 7.4.2.3.a) crosswise to a 5 mm
gap according to the figure below (here: 1 to 22) according to the tech-
nical documentation or the name plate.
8.
Tighten the nuts framed in Figure 7.4.2.3.b and Figure 7.4.2.3.c on the
two adjoining panels "II" and "III" to the permitted gap size according to
the technical documentation or the name plate.
!
When tightening, proceed alternately from the centre of the line of bolts
framed in red of the adjoining panel "II" towards the outside.
!
When tightening, proceed alternately from the centre of the line of bolts
framed in red of the adjoining panel "III" towards the outside.
Done.