background image

   

7   

SOURCE:VOLT   10V   
..<delay>   

   

Connecting   a   Device   in   Track   Mode   to   Create   a   Bipolar   Supply   

   
Connect   two   wires   from   either   the   front   panel   binding   posts   or   the   rear   panel   terminals,   as   shown   in   
Figure   3   below,   to   your   DUT.      The   SENSE   lines   are   optional   (rear   panel   only)   and   are   used   in   a   remote   
sense   connection.   

DUT

0-30V

0-30V

0-6V

+VDD

-VDD

I

DUT

COM

FRONT PANEL

H

L

+

-

-

+

O

u

t

S

e
n
s
e

CHANNEL 1

O

u

t

S

e
n
s
e

+

-

-

+

O

u

t

S

e
n
s
e

CHANNEL 2

O

u

t

S

e
n
s
e

+

-

-

+

O

u

t

S

e
n
s
e

CHANNEL 3

O

u

t

S

e
n
s
e

DUT

+VDD

VDD-

COM

REAR PANEL

SOURCE HIGH

SOURCE LOW

SENSE HIGH

SENSE LOW

   

Figure   3   Connecting   a   Device   in   Track   Mode   on   the   Front   Panel   and   the   Rear   Panel   

   

Turning   On   Multiple   Channels   Sequentially   

   
The   Series   2200   multi-­‐channel   power   supplies   have   all   channels   enabled   in   its   default   state.      The   
following   example   demonstrates   the   steps   to   output   a   voltage   on   each   channel   sequentially,   CH1   (3V)   -­‐>   
CH2   (9V)   -­‐>   CH3   (5V),   and   to   turn   off   each   output   sequentially,   CH3-­‐>CH2-­‐>CH1.         This   example   assumes   
that   all   channels   are   disabled   on   a   2230-­‐30-­‐1.   

CH1

CH2

CH3

   

Front   Panel   Operation   

STEP   1   Configuring   the   Output   Voltages   and   Current   Limit   on   each   channel   

1.

 

Press   CH1.   

2.

 

Press   V-­‐Set.   

3.

 

Use   the   arrow   keys,   numeric   keypad,   or   the   navigation   wheel   to   enter   the   desired   voltage   
output   value,   or   3V   in   this   example.   

4.

 

Press   Enter   to   set   the   voltage.   

5.

 

Press   I-­‐Set.   

6.

 

Use   the   arrow   keys,   numeric   keypad,   or   the   navigation   wheel   to   enter   a   current   limit.   

Summary of Contents for Series 2200

Page 1: ...o select Enable Channels 3 Press Enter to enter the submenu 4 Use the arrow keys or the navigation wheel to select Enable Disable CH2 5 Press Enter to enter the submenu 6 Use the arrow keys or the nav...

Page 2: ...channel 1 and 2 Front Panel Operation STEP 1 Configure the Instrument to Series Combination 1 Press Menu 2 Use the arrow keys or the navigation wheel to select Combine CH1 CH2 3 Press Enter to enter t...

Page 3: ...t S e n s e CHANNEL 2 O u t S e n e O u t S e n s e CHANNEL 3 O u t S e n s e REAR PANEL SOURCE HIGH SOURCE LOW SENSE HIGH SENSE LOW Figure 1 Connecting a Device in Series Combination on the Front Pa...

Page 4: ...limit 12 Press Enter to set the current of the combined channel STEP 3 Turning on the Output 13 Press Output On Off Remote Operation The following SCPI command example configures the power supply for...

Page 5: ...2 Press V Set 3 Use the arrow keys numeric keypad or the navigation wheel to enter a voltage output e g 10V 4 Press Enter to set the voltage of the combined channel 5 Press I Set 6 Use the arrow keys...

Page 6: ...will change the other channel by the desired ratio Remote Operation The following SCPI command example sets CH1 voltage output to 10V the current limit to 1 5A CH2 voltage output to track half of CH1...

Page 7: ...n the Front Panel and the Rear Panel Turning On Multiple Channels Sequentially The Series 2200 multi channel power supplies have all channels enabled in its default state The following example demonst...

Page 8: ...nable Disable CH1 26 Press Enter to enter the submenu 27 Use the arrow keys or the navigation wheel to select Enable CH1 default 28 Press Enter to enable channel 1 29 Press Esc a couple of times to re...

Page 9: ...e arrow keys or the navigation wheel to select Disable CH2 61 Press Enter to disable channel 2 and turn off channel 2 s output voltage 62 Press Esc a couple of times to return to the main display STEP...

Page 10: ...nnel 3 turn on using the appropriate command syntax of the programming environment INST SEL CH3 SOURCE OUTP ENAB ON perform tests on the load INST SEL CH3 SOURCE OUTP ENAB OFF insert desired amount of...

Reviews: