background image

   

9   

45.

 

Press   Enter   to   enable   channel   3   and   output   channel   3’s   configured   voltage.   

46.

 

Press   Esc   a   couple   of   times   to   return   to   the   main   display.   

STEP   6   Disabling   Channel   3   

47.

 

Press   Menu.   

48.

 

Use   the   arrow   keys,   or   the   navigation   wheel   to   select   

Enable   Channels

.   

49.

 

Press   Enter   to   enter   the   submenu.   

50.

 

Use   the   arrow   keys,   or   the   navigation   wheel   to   select   

Enable/Disable   CH3

.   

51.

 

Press   Enter   to   enter   the   submenu.   

52.

 

Use   the   arrow   keys,   or   the   navigation   wheel   to   select   

Disable   CH3

.   

53.

 

Press   Enter   to   disable   channel   3   and   turn   off   channel   3’s   output   voltage.   

54.

 

Press   Esc   a   couple   of   times   to   return   to   the   main   display.   

STEP   7   Disabling   Channel   2   

55.

 

Press   Menu.   

56.

 

Use   the   arrow   keys,   or   the   navigation   wheel   to   select   

Enable   Channels

.   

57.

 

Press   Enter   to   enter   the   submenu.   

58.

 

Use   the   arrow   keys,   or   the   navigation   wheel   to   select   

Enable/Disable   CH2

.   

59.

 

Press   Enter   to   enter   the   submenu.   

60.

 

Use   the   arrow   keys,   or   the   navigation   wheel   to   select   

Disable   CH2

.   

61.

 

Press   Enter   to   disable   channel   2   and   turn   off   channel   2’s   output   voltage.   

62.

 

Press   Esc   a   couple   of   times   to   return   to   the   main   display.   

   

STEP   8   Disabling   Channel   1   

63.

 

Press   Menu.   

64.

 

Use   the   arrow   keys,   or   the   navigation   wheel   to   select   

Enable   Channels

.   

65.

 

Press   Enter   to   enter   the   submenu.   

66.

 

Use   the   arrow   keys,   or   the   navigation   wheel   to   select   

Enable/Disable   CH1

.   

67.

 

Press   Enter   to   enter   the   submenu.   

68.

 

Use   the   arrow   keys,   or   the   navigation   wheel   to   select   

Disable   CH1

.   

69.

 

Press   Enter   to   disable   channel   1   and   turn   off   channel   1’s   output   voltage.   

70.

 

Press   Esc   a   couple   of   times   to   return   to   the   main   display.   

   

Remote   Operation   

   
The   following   SCPI   command   example   assumes   that   all   channels   are   disabled.      The   command   sequence   
sets   the   voltage   output   to   3V,   9V   and   5V   on   CH1,   CH2   and   CH3,   respectively,   sets   all   the   current   limits   to   
1.5A,   turns   the   output   on   sequentially   from   CH1   to   CH2   to   CH3   and   turns   off   each   output   from   CH3   to   
CH2   to   CH1.   
   

INST:SEL   CH1   
SOURCE:VOLT   3V   
SOURCE:CURR   1.5A   
INST:SEL   CH2   
SOURCE:VOLT   9V   
SOURCE:CURR   1.5A   

Summary of Contents for Series 2200

Page 1: ...o select Enable Channels 3 Press Enter to enter the submenu 4 Use the arrow keys or the navigation wheel to select Enable Disable CH2 5 Press Enter to enter the submenu 6 Use the arrow keys or the nav...

Page 2: ...channel 1 and 2 Front Panel Operation STEP 1 Configure the Instrument to Series Combination 1 Press Menu 2 Use the arrow keys or the navigation wheel to select Combine CH1 CH2 3 Press Enter to enter t...

Page 3: ...t S e n s e CHANNEL 2 O u t S e n e O u t S e n s e CHANNEL 3 O u t S e n s e REAR PANEL SOURCE HIGH SOURCE LOW SENSE HIGH SENSE LOW Figure 1 Connecting a Device in Series Combination on the Front Pa...

Page 4: ...limit 12 Press Enter to set the current of the combined channel STEP 3 Turning on the Output 13 Press Output On Off Remote Operation The following SCPI command example configures the power supply for...

Page 5: ...2 Press V Set 3 Use the arrow keys numeric keypad or the navigation wheel to enter a voltage output e g 10V 4 Press Enter to set the voltage of the combined channel 5 Press I Set 6 Use the arrow keys...

Page 6: ...will change the other channel by the desired ratio Remote Operation The following SCPI command example sets CH1 voltage output to 10V the current limit to 1 5A CH2 voltage output to track half of CH1...

Page 7: ...n the Front Panel and the Rear Panel Turning On Multiple Channels Sequentially The Series 2200 multi channel power supplies have all channels enabled in its default state The following example demonst...

Page 8: ...nable Disable CH1 26 Press Enter to enter the submenu 27 Use the arrow keys or the navigation wheel to select Enable CH1 default 28 Press Enter to enable channel 1 29 Press Esc a couple of times to re...

Page 9: ...e arrow keys or the navigation wheel to select Disable CH2 61 Press Enter to disable channel 2 and turn off channel 2 s output voltage 62 Press Esc a couple of times to return to the main display STEP...

Page 10: ...nnel 3 turn on using the appropriate command syntax of the programming environment INST SEL CH3 SOURCE OUTP ENAB ON perform tests on the load INST SEL CH3 SOURCE OUTP ENAB OFF insert desired amount of...

Reviews: