background image

KL25164 - 

Cannular Fully Automatic - Single Lane

 

 
 

Page 

13

 of 

13 

www.KegLand.com.au

 

Last Updated 1/07/2022 9:44 AM

 

 
 

Warranty and Support (Australia) 

To lodge a warranty claim in Australia please forward as many visual pieces of supporting 

information and a detailed description of your issue to  

If you purchased your unit from an international distributor, you will be required to go 

through their warranty claims process.  

For full terms and conditions, please visit our website here -

Terms & Conditions

 

 

Summary of Contents for Cannular

Page 1: ...ar Fully Automatic Single Lane Page 1 of 13 www KegLand com au Last Updated 1 07 2022 9 44 AM Quick Start Manual Fully Automatic Cannular Canning Machine Single Lane KegLand Distribution PTY LTD www K...

Page 2: ...Beverage Line Liquid Flow Meter 4 2 2 Compressed Air Inlet 5 2 3 CO2 Inlet for Purging 6 2 4 Sanitiser Inlet Pre Can Filling Sanitiser Spray and Post Seam Spritz 7 2 5 Can Lid Dropper Apparatus 8 3 0...

Page 3: ...f cans that are within specification as a result of wider double seam tolerances 1 0 Level your Cannular using a spirit level in relation to the filling seaming table The Fully Automatic Cannular feat...

Page 4: ...mp Your beverage line will be attached here Please note we recommend to pre chill your beverage down so that carbonation levels can remain as steady as possible We have found using a G40 set to 2 C wi...

Page 5: ...Fitting Requirements The Cannular requires an inlet air pressure of 100psi 7 BAR to function optimally The Filter Water trap will need to be emptied on a regular basis depending on your air quality A...

Page 6: ...1 07 2022 9 44 AM 2 3 CO2 Inlet for Purging Inlet Fitting 8mm OD Push In Fitting We recommend not exceeding 3psi worth of CO2 for the oxygen reducing purging pre filling process Please note depending...

Page 7: ...ated 1 07 2022 9 44 AM 2 4 Sanitiser Inlet Pre Can Filling Sanitiser Spray and Post Seam Spritz Inlet Fitting 13mm OD Barb x 1 2 Male Thread Please note DO NOT EXCEED 15PSI this silicone hosing cannot...

Page 8: ...id dropper you must disconnect the air supply to the unit 2 5 1 Manually drop a lid in from the magnetic block access port Ring pull facing away from you 2 5 2 Unscrew Loosen to the point of falling o...

Page 9: ...he Bump Stop Shaft and a 24mm Spanner for the Locking Nut Depending on the can size you are using 2 6 4 Rotate the bump stop shaft further down with your hand Its best to go further down than you need...

Page 10: ...from a tap 3 2 If you have adjusted from a 500mL Can you will need to increase the Timer Settings of the first Can Raise Delay or else the First Operation roller will start to engage before the can i...

Page 11: ...it has gone out of specification during transit or over the course of its life you may need to adjust the position of the rollers to achieve a hermetic double seam which is within tolerances We recomm...

Page 12: ...n the thread to adjust the stroke length of the piston This stroke length will correlate with how close the roller ends up to the chuck For example a longer stroke length less thread visible behind th...

Page 13: ...odge a warranty claim in Australia please forward as many visual pieces of supporting information and a detailed description of your issue to If you purchased your unit from an international distribut...

Reviews: