2.5
–
Can Lid Dropper Apparatus
This section will require adjustment out of box if you are
not
using 500mL cans. For a complete
walkthrough process, the cans tested would ideally be filled with carbonated water. Or still water if
sparkling is not available.
Before adjusting the height of the can lid dropper you must disconnect the air supply to the unit.
2.5.1
- Manually drop a lid in from the magnetic block access port. Ring pull facing away from you.
2.5.2
–
Unscrew / Loosen (to the point of falling off) the two retaining socket head screw caps on
each side of the can lid dropper apparatus. With the 5mm Allen key in your toolkit.
2.5.3
–
Lower the apparatus to your desired can height. To test if the height is correct, push a can
through with your hands. The can should not jam on the next spring apparatus (foam dampener).
2.5.4
–
Once your desired height is reached, tighten the retaining SHCS back in firmly.