A.2 Power section current data, 24 A to 210 A controller, air-cooled
U
Mains
F
S
Unit
D3-DA 320/A-24xx
(BG3)
D3-DA 320/A-32xx
(BG3)
D3-DA 310/A-45xx
(BG3)
D3-DA 320/A-45xx
(BG3)
D3-DA 310/A-80xx
(BG3)
D3-DA 310/A-A3xx
(BG4)
D3-DA 310/A-B1xx
(BG4)
Rated current
230 V /
400 V
2 kHz
A
24.00
32.00
45.00
45.00
80.00
130.00
210.00
Maximum current
A
72.00
96.00
135.00
135.00
240.00
280.00
440.00
Duration of maximum current
ms
500.00
500.00
500.00
500.00
400.00
200.00
200.00
Overcurrent
A
48.00
64.00
90.00
90.00
160.00
200.00
315.00
Duration of overcurrent
s
10.00
10.00
10.00
10.00
10.00
10.00
10.00
Maximum current for F
M
= 0 Hz
A
61.38
81.74
114.98
114.98
195.44
280.00
395.98
Rated current
230 V /
400 V
4 kHz
A
24.00
32.00
45.00
45.00
80.00
130.00
210.00
Maximum current
A
72.00
96.00
135.00
135.00
240.00
280.00
347.00
Duration of maximum current
ms
300.00
300.00
300.00
300.00
250.00
200.00
200.00
Overcurrent
A
48.00
64.00
90.00
90.00
160.00
200.00
250.00
Duration of overcurrent
s
10.00
10.00
10.00
10.00
10.00
10.00
10.00
Maximum current for F
M
= 0 Hz
A
51.76
69.01
97.02
97.02
164.90
220.00
291.33
Rated current
230 V /
400 V
8 kHz
A
16.10
21.50
30.20
30.20
53.70
65.00
120.00
Maximum current
A
45.30
60.40
85.00
85.00
144.50
123.87
200.00
Duration of maximum current
ms
500.00
500.00
500.00
500.00
500.00
200.00
200.00
Overcurrent
A
32.20
43.00
60.40
60.40
107.40
123.87
155.00
Duration of overcurrent
s
10.00
10.00
10.00
10.00
10.00
10.00
10.00
Maximum current for F
M
= 0 Hz
A
35.78
47.66
67.03
67.03
113.84
135.11
178.19
Rated current
230 V /
400 V
12 kHz
A
11.30
15.10
21.20
21.20
37.70
–
–
Maximum current
A
34.70
46.20
65.00
65.00
110.50
–
–
Duration of maximum current
ms
500.00
500.00
500.00
500.00
500.00
–
–
Overcurrent
A
22.60
30.20
42.40
42.40
75.40
–
–
Duration of overcurrent
s
10.00
10.00
10.00
10.00
10.00
–
–
Maximum current for F
M
= 0 Hz
A
24.01
31.96
44.97
44.97
76.51
–
–
Rated current
230 V /
400 V
16 kHz
A
8.30
11.10
15.60
15.60
27.70
–
–
Maximum current
A
26.70
35.60
50.00
50.00
85.00
–
–
Duration of maximum current
ms
500.00
500.00
500.00
500.00
500.00
–
–
Overcurrent
A
16.60
22.20
31.20
31.20
55.40
–
–
Duration of overcurrent
s
10.00
10.00
10.00
10.00
10.00
–
–
Maximum current for F
M
= 0 Hz
A
17.54
23.48
32.95
32.95
56.14
–
–
Remarks
: Current data per axis in the axis controller 400/480 V AC refer to the feed voltage for the supply unit, firmware release V003.30.00
Table A.2 Current data, KeDrive D3-DA axis controllers BG3 and BG4, air-cooled
Summary of Contents for KeDrive D3-DA BG3
Page 14: ...14 1 Safety Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023 Safety...
Page 24: ...24 1 Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023...
Page 66: ...66 1 Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023...
Page 78: ...78 1 Appendix Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023 Appendix...
Page 82: ...82 1 Glossary Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023 Glossary...
Page 83: ...83 1 Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023...