1 Commissioning
Operation Manual KeDrive D3-DA BG3 and BG4
1804.200B.1-01 Date: 03/2023
Commissioning
KeStudio DriveManager
Function
Open manual mode window
Select operation mode
- Initially U/F (open loop)
Motor acceleration
Motor with low speed
Start motor and check required and actual speed in
Cockpit (U/F operation)
Start motor control
Manual mode activated
NOTE:
You will find further information in relation to "Controlling a drive using
KeStudio DriveManager" and the manual operation window in the
KeDrive D3-DA device help (ID no.: 1404.209B.x).
DANGER!
Risk of injury due to rotating parts on the motor!
Carelessness may result in serious injuries or death.
Before commissioning motors with feather keys in the shaft end, these keys must be reliably
secured against throwing out, if this is not already prevented by drive elements such as belt
pulleys, couplings or similar.
CAUTION!
Damage to the motor due to incorrect operation during motor test run!
Carelessness can result in significant damage to the motor or
machine.
• It is imperative the safety instructions and warnings from chapter 2 are followed during
commissioning. Please note that you yourself are responsible for safe operation.
• Before you start commissioning it must be ensured that the machine will not be damaged
by the test! Pay particular attention to the limitations of the positioning range.
• Certain motors are
only
intended for operation on the drive controller. Direct connection to
the mains supply can cause irreparable damage to the motor.
• The motor surfaces may become extremely hot. No temperature sensitive parts may touch
or be fastened to these areas, appropriate measures to prevent touching must be taken
wherever necessary.
• The temperature sensor installed must be connected to the terminals of the temperature
monitoring system for the drive controller also during the test run to avoid overheating of
the motor.
• The motor holding brake (if installed) should be checked for correct function before
commissioning the motor. Motor holding brakes are only designed for a limited number of
emergency braking operations. Use as a service brake is not allowed.
5.3.3
Serial commissioning
Saving the data:
KeStudio DriveManager screen
Function
Data set for an individual axis
Data set for the complete device
Data set for an axis group
A saved data set can be transferred to other KeDrive D3-DA axis controllers BG3 and
BG4 using KeStudio DriveManager. With the aid of the data set for an axis group,
several devices including the software can be placed in operation. You will find details in
the help system in KeStudio DriveManager.
Summary of Contents for KeDrive D3-DA BG3
Page 14: ...14 1 Safety Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023 Safety...
Page 24: ...24 1 Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023...
Page 66: ...66 1 Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023...
Page 78: ...78 1 Appendix Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023 Appendix...
Page 82: ...82 1 Glossary Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023 Glossary...
Page 83: ...83 1 Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023...