20
DESCRIPTION
QTY
PART #
1
TRANSFORMER 120/208/240/480V
1
056036
2* CIRCUIT BREAKER 3A/250V
1
053338
3
RELAY DPDT 24V AC
2
030844
4
RECTIFIER
1
018321
5
POWER CORD
1
021289
6
CONNECTION 3 CIRCUITS PLUG
1
032210
CONNECTOR CONTACT PIN MALE
3
028309
7
CONNECTOR 2 CIRCUIT CAP
2
032207
CONNECTOR CONTACT PIN FEMALE
2
028308
8
COVER FOR CIRCUIT BREAKER
1
054664
9
PUSH ROD
1
018096
10 SCREW
1
/
4
"-20" X 1
1
/
4
"
1
021091
HEX NUT
1
/
4
-20
1
016383
11 COUPLER ACTUATOR BL
1
054525
RETAINING RING
2
054540
PIN COUPLER ACTUATOR BL
2
054503
12 ACTUATOR 24V DC
1
054510
13 SHAFT ACTUATOR LOWER BL S/S
1
054522
14 CONNECTOR 2 CIRCUIT PLUG
1
032208
CONNECTOR CONTACT PIN MALE
2
028309
15 PIN BASKET LIFT NON ROTATIONAL
1
054760
*This circuit breaker can be found under the control panel on newer units.
6
5
1
2
4
3
8
7
10
9
15
11
14
12
13
NOTES
1. A minimum distance of
3
/
16
" and maximum distance of
1
/
4
" should be maintained when actuator
is at full downward stroke. Item 11 should never be bottomed on item 12 when in this location.
2. Actuator shaft should travel 6
1
/
2
" upward from lowest position.
3. Distance are to be measured when actuator is powered.
4. Apply light coating of food grade grease to Item 9 on entire shaft inside housing.
Housing
Figure 6-8
Basket Lift Power Supply Box
Figure 6-9
Basket Lift Assembly