A 3/4” NPT manual gas valve is factory installed with
each floor model fryer (for single fryers and batteries),
except for 10x11AA – 20AA models which use a 1/2”
NPT valve. The required gas pressure for proper
operation of each fryer is 4” water column for natural
gas and 10” water column for Propane gas at the
burner manifold. Remove the allen head test plug on
the gas manifold and use a manometer to check the
gas pressure.

In-line pressure regulators are not supplied by Keating.
They are to be provided and installed by others as
directed by local codes.

NOTE:

If more than one gas fryer is on the same supply

line, you may require a larger line. Consult your local gas
company to assure adequate volume and pressure.
Refer to serial plate for proper gas requirements for your
particular model.

ELECTRICAL
CONNECTION

The Keating Instant Recovery® Gas fryer is equipped
with a 9’ neoprene covered, 3 wire electrical cord with
a three-pronged grounded plug for protection against
electrical shock. This plug must be placed into a 120V
properly grounded three-pronged outlet (NEMA 5-15 or
5-20). For proper grounding procedures see local
codes or, in the absence of local codes, the current
National Electrical Code ANSI/NFPA 70 or Canadian
Electrical Code CAN 22.2 as applicable.

NOTE:

AA and CMG Models do not require any outside

electrical connections.

NOTE:

The electrical wiring diagram for the fryer is

attached to the inside of the fryer door and to the inside
of this manual.

WARNING

DO NOT CUT OR REMOVE THE GROUNDING
PRONG FROM THIS PLUG.

GAS LEAK
TESTING

Prior to lighting your fryer:

1. Make sure all thermostats, switches and safety

valves are in the “OFF” position.

2. Turn main On/Off manual gas valve to the “ON”

position.

3. Have your plumber or gas company check for

leaks with a soap solution or sniffer. (NEVER check
with an open flame!)

4. Have your plumber or gas company representative

light the constant pilot. (Not necessary if your fryer
has an optional spark ignitor.)

NOTE: 

It is estimated that half of all service calls made

on Keating Instant Recovery® Gas fryers result from
an inadequate gas supply. During installation, have a
gas company representative make certain that the fryer
is receiving adequate gas pressure and volume.

WARNING

PROPANE GAS MAY EVENTUALLY LOSE ITS
ODOR AND PRECAUTIONS SHOULD BE TAKEN TO
ASSURE THAT IT IS NOT PRESENT EVEN THOUGH
YOU DO NOT DETECT AN ODOR. IF THERE IS ANY
DOUBT, YOU SHOULD CALL YOUR LOCAL
PROPANE GAS SUPPLIER FOR ASSISTANCE.

III OPERATING

FILLING

NOTE:

Before filling the fryer make certain the fryer 

vessel is sanitized, dry and the drain valve is 
completely closed. See figure 3-4 on page 7 for
location of drain valve.

CAUTION:

We recommend that solid shortening not be

used in AA and CMG Model fryers as they are not
equipped with a melt cycle. If solid shortening is used,
it should be melted prior to filling the fryer vessel.
Damage done by melting solid shortening in the fryer
vessel will void the warranty.

WARNING

BE SURE THE HEAT TRANSFER TUBES ARE
COMPLETELY COVERED WITH OIL BEFORE
SWITCHING THE FRYER ON. IF OIL LEVEL DROPS
BELOW TOP OF HEAT TRANSFER TUBES,
SEVERE DAMAGE TO FRYER AND INJURY TO
OPERATOR MAY RESULT!

WARNING

WATER (IN ANY FORM) AND HOT OIL DON’T MIX!!!

Summary of Contents for GAS FRYER

Page 1: ...INSTANT RECOVERY GAS FRYER SERVICE MANUAL KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicago com...

Page 2: ...nance 10 Oil Breakdown 10 Limited Calibration 10 Thermostat Bulb Positioning 11 Hi Limit Check 11 SECTION V SERVICE DIAGNOSIS General 11 Trouble Shooting Charts 12 13 SECTION VI PARTS LIST Ordering Pa...

Page 3: ...STALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VIC...

Page 4: ...ustibles You must maintain the following minimum clearances from combustible and noncombustible construction You must install this appliance at least 16 inches away from any open flame Adequate cleara...

Page 5: ...R OTHER REPRODUCTIVE HARM II INSTALLATION This fryer MUST be installed inspected calibrated and serviced by qualified and or certified and or licensed service personnel you may void your Keating warra...

Page 6: ...current ANSI Z21 41 CAN 1 6 9 standard for quick disconnect devices for use with gas fuel as applicable WARNING IF DISCONNECTION OF THE RESTRAINT IS NECESSARY IT MUST BE RECONNECTED WHEN THE FRYER IS...

Page 7: ...NDING PRONG FROM THIS PLUG GAS LEAK TESTING Prior to lighting your fryer 1 Make sure all thermostats switches and safety valves are in the OFF position 2 Turn main On Off manual gas valve to the ON po...

Page 8: ...gas supply to unit usually at rear by turning handle in line with gas piping or hose Also open manual valve red gas cock on gas piping inside unit where applicable 2 Light the constant pilot located...

Page 9: ...TING PROCEDURES USE ONLY KEATING APPROVED BASKETS IN YOUR FRYER NEVER OVERFILL FRY BASKETS DO NOT BANG BASKETS ON BASKET HANGERS OR FRYER VESSEL CARE SHOULD BE TAKEN WHEN LOWERING BASKETS INTO FRYER T...

Page 10: ...DRAINING WARNING ALWAYS SHUT THE FRYER OFF COMPLETELY BEFORE DRAINING THE FRYER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL A DRAIN PIPE AND COVERED CONTAINER SUITABLE F...

Page 11: ...ent accidental spillage 5 Fill fryer vessel to Fill Level line with water WARNING UNDER NO CIRCUMSTANCES SHOULD THE FRYER BE LEFT UNATTENDED DURING BOIL OUT TRAINED PERSONNEL MUST BE PRESENT DURING TH...

Page 12: ...a clearly visible and accurate display and are very easy to use PROGRAMMING To program the timers the unit must be in the idle mode Press and hold the set button for approximately two seconds The disp...

Page 13: ...formance A Oil Breakdown As part of a Preventive Maintenance Program the oil in your fryer needs to be filtered regularly to avoid breakdown The initial investment in the frying system is less than th...

Page 14: ...back 3 Apply oil resistant flexible sealant onto compression fitting thread before installing fitting into fryer vessel 4 Position bent portion of bulb against far right heat transfer tube and instal...

Page 15: ...ot b Turn fryer and manual gas valve off orifice s Clean orifice s and pilot tube c Low pilot flame height c Adjust pilot flame height d Flame switch control is faulty d If it takes more than 60 secon...

Page 16: ...oil d Check with oil supplier for higher grade oil e Fryer is overheating and Hi Limit e Check thermostat calibration control has failed and bulb position See pages 10 11 and replace thermostat if ne...

Page 17: ...LVE ALL 004266 1 1 1 1 1 1 6 RUNNER PILOT AIR SHUTTER NIPPLE W NUT 015747 1 1 2 2 2 3 CLIP 004090 1 1 2 2 2 3 7 RUNNER PILOT ORIFICE CALL 1 800 KEATING 1 1 2 2 2 3 8 RUNNER PILOT ORIFICE HOLDER STRAIG...

Page 18: ...15 TS CONTROL PANEL AA CMG CONTROL PANEL BB CONTROL PANEL GAS FRYER ASSEMBLY...

Page 19: ...16 RUNNER PILOT ASSEMBLY See Page 16 for part numbers...

Page 20: ...L PLATE 1 030833 3 THERMOSTAT KNOB 1 004163 4 RETAINING SCREWS 3 004610 5 FRY ON OFF SWITCH PLATE 1 007997 6 TOGGLE SWITCH FRY ON OFF 1 004499 7 HI LIMIT TEST PLATE 1 004305 8 HI LIMIT TEST BUTTON 1 0...

Page 21: ...ITCH MAIN ON OFF BB TS 1 004499 9 HI LIMIT TEST BUTTON BB TS 1 004304 10 TIMER ELECTRONIC TS 2 023709 11 MELT CONTROL BB TS 1 004169 12 NUT WITH BOOT BB TS 1 009389 13 CONTROL PANEL HOODED BB TS 1 14...

Page 22: ...E SWITCH FRY OFF MELT 1 000521 8 TOGGLE SWITCH MAIN ON OFF 1 004499 9 HI LIMIT TEST BUTTON 1 004304 10 TIMER ELECTRONIC 2 023709 11 MELT CONTROL 1 004169 12 NUT WITH BOOT 1 009389 13 CONTROL PANEL HOO...

Page 23: ...ITCH BUZZER LIMIT 2 004592 8 MOTOR CCW LEFT Viewing front of fryer 1 000390 9 MOTOR CW RIGHT Viewing front of fryer 1 000391 10 BUZZER ON OFF SWITCH WITH PLATE 1 004499 11 BUZZER 1 004223 12 WIRE HARN...

Page 24: ...ROD 2 015817 ROLLER PIN 2 016393 ROLLER PIN LOCK 2 016392 5 LIFT ROD FOR SPLIT BASKETS 2 020086 6 BUSHING PUSH ROD 4 016405 7 BUSHING RETAINING RING 4 015831 8 FUSE HOLDER 2 004335 9 FUSE ACTUATOR GRO...

Page 25: ...of this manual and should be saved for troubleshooting and maintenance The wiring diagrams in this section cover standard fryers which may or may not match the diagrams sent with the fryer Non standa...

Page 26: ...23 BB WIRING DIAGRAM TS WIRING DIAGRAM...

Page 27: ...18 AND ABOVE TS WITH BASKET LIFT WIRING DIAGRAM 24 14 TS WITH BASKET LIFT WIRING DIAGRAM...

Page 28: ...TY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installation or main...

Page 29: ...NUMBER __________________________ SERIAL NUMBER ____________________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS __________________________________________ TOP SIDE COOKER HOT PLATE PASTA PLUS...

Reviews: