WARNING
WHEN YOUR FRYER IS BEING USED IN
CONJUNCTION WITH A
CENTRAL
FILTER,
DISCONNECT POWER SUPPLY
BEFORE
RESETTING MOTOR TO PREVENT SERIOUS
INJURY WHEN RESET SWITCH IS ENGAGED (SEE
FILTER MANUAL).
16. Check thermostat bulb positioning – see page 10.
17. Refill the fryer with new or filtered oil.
ELECTRONIC
TIMERS
The electronic timers provide a clearly visible and
accurate display and are very easy to use. This
procedure resets the timer to operate in
minutes:seconds.
A. TIMER OPERATION
B. How to program the “Keating” Electronic
Timer
STEP 1
Make certain power to the timer has been OFF for at least
30 seconds. Then PRESS and hold down the UP arrow
button while turning the rocker power switch to the ON
position.
Note
: If power switch does not turn off timers, the unit must
be unplugged (two people may be needed).
The timer will turn ON and the display will now be indicating
OR
The BEEPER will BEEP 4 times.
If STEP 1 was OK, proceed to STEP 2. If not, retry Step 1
making sure the power was OFF for at least 30 seconds or
more.
STEP 2
PRESS all 3 buttons in sequence: left-center-right.
The BEEPER will BEEP when each button is
pressed. If BEEPER does not BEEP, the timer is
defective. STOP TESTING. Reset procedure is
completed when 1:00 appears on the digital
display.
OPTIONAL TIMER
OPERATING INSTRUCTIONS
PART # 056921
DIGITAL TIMERS
The electronic timers, standard on TS &
IFM models, provide a clearly visible and
accurate display and are very easy to use.
PROGRAMMING
To program the timers, the unit must be in the idle mode.
Press and hold the set button for approximately two
seconds. The display will show “SEt”. Press the button for
the channel to be programmed. The display will show the
current setting for that channel. Use the up or down button
to increment or decrement the setting. When the setting is
correct, press and hold the set button again for
approximately two seconds. The display will show "StO"
for approximately two seconds and the timer will return to
normal operation. Repeat the process as necessary for
the other timers.
OPERATING LOGIC
When the timer is powered up, the display will show the
time setting for the channel that was operated last and the
relay output contacts will be open. To start a cycle, press
the desired channel button (1-3). The display will begin to
countdown from the preset time setting and the relay
– – – –
– – – –
TIMER
ACTION
OFF
ON
PAUSED
END OF CYCLE
LED
OFF
FLASHING
STEADY
STEADY
FLASHES
“00:00”
DISPLAY
03:00
SET
TIME
COUNTING
DOWN
FLASHES
TIME
REMAINING
START/STOP BUTTON
Push to
START
new cycle or to restart paused cycle
Push to
PAUSE
(STOP) cycle in progress
Push and hold 2 seconds to
RESET
stopped
(PAUSED or COMPLETED) cycle
TIME SELECT BUTTONS
Push
DOWN ARROW
to decrease set time
Push
UP ARROW
to increase set time
REAR VIEW
AUDIBLE ALARM
Beeps at
END OF CYCLE
Push and hold
START/STOP
Button to
RESET
timer
OUTPUT RELAY
Energized when timer is
“ON”
(display counting down)
De-energized when timer is
“OFF”
, at
END OF CYCLE
, or
PAUSED
9
1:00
O
O
Summary of Contents for GAS FRYER
Page 18: ...15 TS CONTROL PANEL AA CMG CONTROL PANEL BB CONTROL PANEL GAS FRYER ASSEMBLY...
Page 19: ...16 RUNNER PILOT ASSEMBLY See Page 16 for part numbers...
Page 26: ...23 BB WIRING DIAGRAM TS WIRING DIAGRAM...
Page 27: ...18 AND ABOVE TS WITH BASKET LIFT WIRING DIAGRAM 24 14 TS WITH BASKET LIFT WIRING DIAGRAM...