background image

2

Installed in accordance with all local codes, or in
the absence of local codes, with the current
National Fuel Gas Code Z223.1/NFPA 54, Natural
Gas Installation CAN/CGA-B149.1 or Propane
Installation Code CAN/CGA-B149.2

Installed under a properly designed operating
exhaust hood.

Connected to the type of gas for which the fryer is
manufactured.

Pressure regulator installed in the appliance is
adjusted for the manifold pressure marked on the
serial plate.

Adequate air supply to the fryer.

In-line pressure regulator, not supplied by Keating,
must be installed outside the appliance (when
needed to maintain the specificied manifold pressure
marked on the serial plate).

The equipment is operated in the manner intended
using the proper utensils.

Keep the equipment clean and have it checked
periodically.

Burner air adjustments, mechanical maintenance
and repairs must be performed by qualified service
personnel.

If the equipment is not installed, operated and
maintained in accordance with the above,
concentrations of carbon monoxide in excess of the
established limits could be present in the kitchen
environment.

ALL PERSONNEL IN THE WORK PLACE WHO MAY
BE SUBJECT TO ANY EXPOSURE OF CARBON
MONOXIDE MUST BE WARNED OF SUCH
POSSIBLE EXPOSURE. THIS WARNING SHOULD
BE CONVEYED IN A MANNER SO THAT IT IS
CLEARLY UNDERSTOOD BY THE EMPLOYEE, AND
THE EMPLOYEE SHOULD BE ASKED IF IN FACT HE
OR SHE UNDERSTANDS THE CORRECT METHOD
OF OPERATION OF THE EQUIPMENT AND THAT A
RISK OF EXPOSURE EXISTS IF THE EQUIPMENT
IS OPERATED IMPROPERLY.

WARNING

IF NOT INSTALLED, OPERATED AND MAINTAINED
IN ACCORDANCE WITH THE MANUFACTURER’S
INSTRUCTIONS, THIS PRODUCT COULD EXPOSE
YOU TO SUBSTANCES IN FUEL OR IN FUEL
COMBUSTION WHICH CAN CAUSE DEATH OR
SERIOUS ILLNESS AND WHICH ARE KNOWN TO
THE STATE OF CALIFORNIA TO CAUSE CANCER,
BIRTH DEFECTS OR OTHER REPRODUCTIVE
HARM.

II INSTALLATION

This fryer MUST be installed, inspected, calibrated and
serviced by qualified and/or certified and/or licensed
service personnel – you may void your Keating
warranty if installation is not completed per current
local, national and Keating specifications. Contact your
dealer for assistance.

DAMAGE DURING
SHIPMENT

The fryer has been assembled, tested and inspected at
the factory. Upon arrival, the complete fryer should be
checked for any damage that may have occurred
during shipment.

The carrier is responsible for all damage in transit
whether visible or concealed. Do not pay for the freight
bill until the fryer has been thoroughly checked for
damage. If concealed damage is found later, contact
the carrier immediately to file a claim.

What to do if equipment arrives damaged:

VISIBLE LOSS OR DAMAGE—Be certain to note this
on the freight or express receipt and have it signed by
the delivery person.

FILE CLAIM FOR DAMAGES IMMEDIATELY –
Regardless of extent of damage.

CONCEALED LOSS OR DAMAGE—If damage is
noticed when equipment is unpacked, notify the freight
company immediately, and file a “concealed damage
claim”. This MUST be done immediately. Be sure to
retain the shipping container for inspection.

Keating does not assume responsibility for Loss OR
Damage incurred in transit.

INSTALLATION

Installation must conform with local codes or, in
absence of local codes, with the current National Fuel
Gas Code Z223.1/NFPA 54, Natural Gas Installation
CAN/CGA–B149.1 or Propane Installation Code
CAN/CGA-B149.2. 

POSITIONING

The fryer must be no closer than 6 inches from any
combustible material and 16 inches away from any
open flame. The fryer must be placed under an exhaust
hood with a fire retardant system. Your ventilation
hood, when installed, must conform to the current
ANSI/NFPA 96 standard. 

ALL

connections and

placement must comply with local and national codes.
It is the responsibility of the owner and local installer to
comply with these regulations when installing the fryer.

Summary of Contents for GAS FRYER

Page 1: ...INSTANT RECOVERY GAS FRYER SERVICE MANUAL KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicago com...

Page 2: ...nance 10 Oil Breakdown 10 Limited Calibration 10 Thermostat Bulb Positioning 11 Hi Limit Check 11 SECTION V SERVICE DIAGNOSIS General 11 Trouble Shooting Charts 12 13 SECTION VI PARTS LIST Ordering Pa...

Page 3: ...STALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VIC...

Page 4: ...ustibles You must maintain the following minimum clearances from combustible and noncombustible construction You must install this appliance at least 16 inches away from any open flame Adequate cleara...

Page 5: ...R OTHER REPRODUCTIVE HARM II INSTALLATION This fryer MUST be installed inspected calibrated and serviced by qualified and or certified and or licensed service personnel you may void your Keating warra...

Page 6: ...current ANSI Z21 41 CAN 1 6 9 standard for quick disconnect devices for use with gas fuel as applicable WARNING IF DISCONNECTION OF THE RESTRAINT IS NECESSARY IT MUST BE RECONNECTED WHEN THE FRYER IS...

Page 7: ...NDING PRONG FROM THIS PLUG GAS LEAK TESTING Prior to lighting your fryer 1 Make sure all thermostats switches and safety valves are in the OFF position 2 Turn main On Off manual gas valve to the ON po...

Page 8: ...gas supply to unit usually at rear by turning handle in line with gas piping or hose Also open manual valve red gas cock on gas piping inside unit where applicable 2 Light the constant pilot located...

Page 9: ...TING PROCEDURES USE ONLY KEATING APPROVED BASKETS IN YOUR FRYER NEVER OVERFILL FRY BASKETS DO NOT BANG BASKETS ON BASKET HANGERS OR FRYER VESSEL CARE SHOULD BE TAKEN WHEN LOWERING BASKETS INTO FRYER T...

Page 10: ...DRAINING WARNING ALWAYS SHUT THE FRYER OFF COMPLETELY BEFORE DRAINING THE FRYER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL A DRAIN PIPE AND COVERED CONTAINER SUITABLE F...

Page 11: ...ent accidental spillage 5 Fill fryer vessel to Fill Level line with water WARNING UNDER NO CIRCUMSTANCES SHOULD THE FRYER BE LEFT UNATTENDED DURING BOIL OUT TRAINED PERSONNEL MUST BE PRESENT DURING TH...

Page 12: ...a clearly visible and accurate display and are very easy to use PROGRAMMING To program the timers the unit must be in the idle mode Press and hold the set button for approximately two seconds The disp...

Page 13: ...formance A Oil Breakdown As part of a Preventive Maintenance Program the oil in your fryer needs to be filtered regularly to avoid breakdown The initial investment in the frying system is less than th...

Page 14: ...back 3 Apply oil resistant flexible sealant onto compression fitting thread before installing fitting into fryer vessel 4 Position bent portion of bulb against far right heat transfer tube and instal...

Page 15: ...ot b Turn fryer and manual gas valve off orifice s Clean orifice s and pilot tube c Low pilot flame height c Adjust pilot flame height d Flame switch control is faulty d If it takes more than 60 secon...

Page 16: ...oil d Check with oil supplier for higher grade oil e Fryer is overheating and Hi Limit e Check thermostat calibration control has failed and bulb position See pages 10 11 and replace thermostat if ne...

Page 17: ...LVE ALL 004266 1 1 1 1 1 1 6 RUNNER PILOT AIR SHUTTER NIPPLE W NUT 015747 1 1 2 2 2 3 CLIP 004090 1 1 2 2 2 3 7 RUNNER PILOT ORIFICE CALL 1 800 KEATING 1 1 2 2 2 3 8 RUNNER PILOT ORIFICE HOLDER STRAIG...

Page 18: ...15 TS CONTROL PANEL AA CMG CONTROL PANEL BB CONTROL PANEL GAS FRYER ASSEMBLY...

Page 19: ...16 RUNNER PILOT ASSEMBLY See Page 16 for part numbers...

Page 20: ...L PLATE 1 030833 3 THERMOSTAT KNOB 1 004163 4 RETAINING SCREWS 3 004610 5 FRY ON OFF SWITCH PLATE 1 007997 6 TOGGLE SWITCH FRY ON OFF 1 004499 7 HI LIMIT TEST PLATE 1 004305 8 HI LIMIT TEST BUTTON 1 0...

Page 21: ...ITCH MAIN ON OFF BB TS 1 004499 9 HI LIMIT TEST BUTTON BB TS 1 004304 10 TIMER ELECTRONIC TS 2 023709 11 MELT CONTROL BB TS 1 004169 12 NUT WITH BOOT BB TS 1 009389 13 CONTROL PANEL HOODED BB TS 1 14...

Page 22: ...E SWITCH FRY OFF MELT 1 000521 8 TOGGLE SWITCH MAIN ON OFF 1 004499 9 HI LIMIT TEST BUTTON 1 004304 10 TIMER ELECTRONIC 2 023709 11 MELT CONTROL 1 004169 12 NUT WITH BOOT 1 009389 13 CONTROL PANEL HOO...

Page 23: ...ITCH BUZZER LIMIT 2 004592 8 MOTOR CCW LEFT Viewing front of fryer 1 000390 9 MOTOR CW RIGHT Viewing front of fryer 1 000391 10 BUZZER ON OFF SWITCH WITH PLATE 1 004499 11 BUZZER 1 004223 12 WIRE HARN...

Page 24: ...ROD 2 015817 ROLLER PIN 2 016393 ROLLER PIN LOCK 2 016392 5 LIFT ROD FOR SPLIT BASKETS 2 020086 6 BUSHING PUSH ROD 4 016405 7 BUSHING RETAINING RING 4 015831 8 FUSE HOLDER 2 004335 9 FUSE ACTUATOR GRO...

Page 25: ...of this manual and should be saved for troubleshooting and maintenance The wiring diagrams in this section cover standard fryers which may or may not match the diagrams sent with the fryer Non standa...

Page 26: ...23 BB WIRING DIAGRAM TS WIRING DIAGRAM...

Page 27: ...18 AND ABOVE TS WITH BASKET LIFT WIRING DIAGRAM 24 14 TS WITH BASKET LIFT WIRING DIAGRAM...

Page 28: ...TY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installation or main...

Page 29: ...NUMBER __________________________ SERIAL NUMBER ____________________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS __________________________________________ TOP SIDE COOKER HOT PLATE PASTA PLUS...

Reviews: