I n s t a l l a t i o n   a n d   O p e r a t i o n   M a n u a l  

FN8130GHPO 
FNL8130GHPO 

 

HPO Fast-Fri Gas Fryer 

 

 

228686-21 

FNB8130GHPO 
FNLB8130GHPO 

Содержание 800 SERIES

Страница 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l FN8130GHPO FNL8130GHPO HPO Fast Fri Gas Fryer 228686 21 FNB8130GHPO FNLB8130GHPO...

Страница 2: ...vice tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Li...

Страница 3: ...Clearances Assembly Electrical Connection Fitting Rear Rollers Gas Connection Commissioning Operation Guide Description of Controls Filling the Tank Lighting Main Burners Setting Operating Temperature...

Страница 4: ...LY TO GUARD IT AGAINST RISK OF FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION...

Страница 5: ...8130GHPO 220 240 V a c 50 Hz 0 5A 1P N E 3 pin 10A cord set fitted Input Rating N H G C 140 MJ hr 140 MJ hr Supply Pressure 1 13 3 40 kPa 2 75 3 40 kPa Burner Operating Pressure 0 87 kPa 2 55 kPa Gas...

Страница 6: ...4...

Страница 7: ...lation person Remove all packaging and transit protection from appliance including all protective plastic coating from door outer panels and exterior stainless steel panels Check equipment and parts f...

Страница 8: ...he appliance can be positioned securely and level This should be carried out on completion of gas connection Refer to Gas Connection Section This appliance can also be fitted with rear rollers to enab...

Страница 9: ...housings 3 Fit rear roller to rear leg housing and align screw hole in side of rear leg housing with threaded hole in rear roller 4 Secure rear roller to leg support with bolt supplied and tighten bo...

Страница 10: ...installed for Gas conversion procedure is shown in this manual b Supply Pressure required for this appliance is shown in Specifications section of this manual Check gas supply to ensure adequate supp...

Страница 11: ...al b Thermostat operation check should be carried out by filling the fryer with oil shortening to the oil FILL LEVEL mark at rear of the tank and setting the thermostat to 180 C Turn ON main burners a...

Страница 12: ...ed Press and release to operate Located Behind Main Access Door GREAT CARE MUST BE TAKEN BY OPERATOR TO USE THE FRYER SAFELY TO GUARD AGAINST RISK OF INJURY AND FIRE DO NOT LEAVE FRYER UN ATTENDED DUR...

Страница 13: ...oiling table burner The liquefied shortening can then be poured into the tank until it reaches the FILL LEVEL mark FN8130GHPO fryer will hold 46 5 lbs shortening Pre Heating NOTE When pre melting shor...

Страница 14: ...control panel will illuminate when burners are On and will go out when oil is at pre set temperature 5 If left or right Red Lock Out indicators illuminate press left or right burner reset switches on...

Страница 15: ...and operating at peak efficiency follow the procedures below 1 At end of each day or at the end of each shift if frying schedule is heavy frying medium should be drained and filtered into a receptacle...

Страница 16: ...ained use a ladle or small pan with a handle and dip into hot frying medium from container and pour around sides and bottom of tank to wash out crumbs and particles adhering to tank 9 Continue to dip...

Страница 17: ...er and rinse thoroughly with water Use a 1 part vinegar to 15 parts water solution to rinse tank and neutralise any cleaner residue If this proves unsuitable for cleaner being used use a weaker soluti...

Страница 18: ...rying oil broken down Check amount of fresh frying medium added to fryer to be sure turnover is adequate Using wrong cooking frying medium Some frying mediums form gums when used in a deep fryer e g s...

Страница 19: ...hermostat setting with a thermometer or thermocouple Rapid breakdown of oil Use a stable frying oil Use of unrefined oils Dripping smokes at lower temperature than refined and deodorised oils Darkenin...

Страница 20: ...ply not On Incorrect gas pressure Incorrect injectors Faulty gas valve Does the flame continue well after sparking stops Broken connection from flame rod to control Bad earthing no poor circuit burner...

Страница 21: ...19...

Страница 22: ...ng bracket 5 Reconnect supply pipe at universal joint 6 Fasten supply pipe to upper mounting bracket 7 Retighten universal joint 8 Attach the supplied 3 4 Male Female galvanised elbow at the end of th...

Страница 23: ...correct plates Refer to Gas Specifications Table at end of this section 1 Connect a manometer to lower test point Operating Pressure on the gas control valve Refer to Fig 12 2 Remove slotted cap to r...

Страница 24: ...as connections for leakage using soapy water or other gas detecting equipment 2 Check the following functions in accordance with operating instructions specified in Operation section of this manual Li...

Страница 25: ...x 9 55 holes 16 x 9 55 holes Operating Pressure 0 87 kPa 2 55 kPa Supply Pressure 1 13 3 40 kPa 2 75 3 40 kPa Main Burner Injectors 4 30mm 2 40mm Aeration Plate 20 x 9 55 holes 16 x 9 55 holes Operat...

Страница 26: ...tch 023160K Burner Blower Kit 024792 Ignition Electrode spark 025383 Ignition Electrode flame 022663 Fuse 2 Amp 227963 Heating indicator Amber 227962 Power Indicator Green 013528 Lock Out Indicator Re...