1-800-KEATING
|
ELECTRIC CUSTOM PASTA SYSTEM - SERIES 2009
11
SERVICE DIAGNOSIS
The following diagnosis is only to be used as a guide to qualifi ed service personnel. Keating recommends that
you use a qualifi ed & licensed service company. (Equipment still under warranty requires it.) Call 1-800-KEATING
if you need assistance in locating a qualifi ed service company.
NOTE:
To correctly and quickly diagnose the system, the chart below should be followed in sequential order.
TROUBLE SHOOTING CHART
PROBLEM
SOLUTIONS (FOLLOW SEQUENTIALLY)
Water always fi lling
a. Clean sensors thoroughly with brush and vinegar.
b. Adjust the sensitivity of the B Board (for the top sensor) fully clockwise.
c. If fi lling persists, ground out the top sensor (if fi lling stops, replace sensor –
Part #010212).
d. If fi lling persists after grounding out the sensor, replace the B Board
(Part #001166)
Water never fi lls
a. Turn water switch (far right) ‘ON.’
b. Clean sensors thoroughly with brush and vinegar.
c. Adjust the sensitivity of the B Board (for the top sensor) fully counterclockwise
(see page 5 - Setting Water Level Control).
d. Remove the wire from the top sensor. If fi lling begins, replace the sensor
(Part #010212).
e. If water does not fi ll, place a jumper wire across terminals A & C on the
B Board. If fi lling begins, replace B Board (Part #001166).
f. If water does not fi ll, replace water solenoid (Part #008133).
Timers counting down in the wrong mode (Not
minutes and seconds)
a. Reset the timer (see instructions on page 7).
Water leaking in the rear of the Custom Pasta
System
a. Replace fi ll hose (Part #037390 – Sold per foot)
Breakers continue to trip
a. Ensure all wires to the contactors, breakers and elements are tight.
b. Verify water is not getting on any components.
c. Check contactors for proper operation.
d. Check continuity of heating elements.
e. Replace breaker.
Heating elements won’t come on
a. Verify operating instructions in the manual.
b. Clean sensors with brush and vinegar.
c. Adjust sensitivity of the A Board (for the lower sensor) fully clockwise (see
page 5 - Setting Water Level Control).
d. Place the wire attached to the lower sensor to the ground (if heating begins,
replace sensor – Part #010212).
e. If heating does not being, place a jumper wire across terminals A&C on the
A Board. If heating begins, replace the A Board (Part #001167).
Unit is out of power
a. Check electrical connection.
b. Check fuses.
c. Check Hi-Limit control.
Summary of Contents for 14 Counter
Page 18: ...keatingofchicago com 16 14 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM...
Page 20: ...keatingofchicago com 18 14 ELECTRIC PASTA WITH BASKET LIFT AND DIGITAL TIMERS WIRING DIAGRAM...
Page 22: ...keatingofchicago com 20 18 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS...
Page 24: ......
Page 25: ......