Specifications
Classification
Equipment not suitable for use in the presence of a flammable anaesthetic mixture with air, oxygen or nitrous oxide.
Medical Equipment
• Type B, Applied Part
• Class II or internally powered Equipment
• IPX0
Dimensions and Therapy Options
Dimensions..................... ..........................................................................7.6” W x 6” H x 2.5” D (19.3 x 15.2 x 6.4 cm)
Weight (with empty canister attached): ...............................................................................................~2.4 lbs (~1.08 kg)
Canister Volume: ............................................................................................................................................... ~300 mL
Pressure Options: ........................................................................................................25 to 200 mmHg (3.3 to 26.6 kPa)
Therapy Delivery Modes: .........................................................................................................Continuous or Intermittent
Electrical Data (Power Supply)
Voltage Input ........................................................................................................................................... 100 - 240 VAC
Frequency .......................................................................................................................................................... 50/60Hz
Amperage ............................................................................................................................................ 0.72A @ 115VAC
External Power Supply Output: ........................................................................................................................12V, 3.3 A
Patient & Enclosure Leakage Current: .................................................................................................... <100 Microamps
Battery Information
Type: .................................................................................................................................................. Lithium-ion (Li-ion)
Properly dispose of in accordance with local, state and federal regulations for Lithium-ion (Li-ion) batteries
Battery Run Life: .................................................................................... Approximately 14 hours, depending on settings.
Battery Charge Time: .......................................................................Approximately 6 hours from a fully discharged state.
Storage and Environmental conditions
Storage Temperature range ..................................................................................................-4°F (-20°C) to 140°F (60°C))
Operational Temperature Range.... .......................................................................................... 41°F (5°C) to 104°F (40°C)
Relative Humidity Range: ........................................................................................................... 0-95% non-condensing
Altitude Range: ................................................................................................................0 to 14,000 feet (0 to 4267 m)
Optimum Performance: ......................................................................................................0 to 8,000 feet (0 to 2438 m)