26 - EN
7.6. REMOTE CONTROL ( optional)
To switch the remote control on, press key K1 or K2 for a prolonged period. On switch-on the remote control rings
and the LED switches on and
fl ashes. The remote control switches off after 30 seconds if not used.
PARAMETERS UPLOAD
Data transfer from the control to the remote control.
To enter the I RDA menu, press K1 for a prolonged period. “UPLOAD PAR” appears on the display.
By pressing key K2 the upload is performed. Avvenuto trasferimento (Transfer performed) appears on the screen.
NB: in board where the NMP parameter exists, the upload is not performed if NMP= 0.
PARAMETERS DOWNLOAD
Data transfer from the remote control to the control.
Press the key K1, pass to the next menu and“DOWNLOAD PAR” will appear on the display.
The download is performed by pressing key K2.
THE DI SPLAY SHOWS “ERROR VERSI ON”
The parameters map is not compatible with the control, the parameters are not downloaded.
THE DI SPLAY SHOWS “ERROR PARAMETERS”
The download has not been concluded correctly, the parameters map contained in the remote control may not be usable.
THE DI SPLAY SHOWS “ERROR”
The parameters map present in the remote control is not downloaded correctly in the control, the parameters are
not accepted.
NB: in the controls where the EDL parameter exists, the download is not performed if EDL= 0.
LOG UPLOAD
Transfer of the entire memory log from the control to the remote control.
Press key K1. “UPLOAD STORE” appears on the display. Press K2 to upload the log.
I f the process is not concluded correctly, “ERROR” appears on the display.
Press the K1 key for a prolonged period to escape the menu.