EN - 19
7. USER I NSTRUCTI ONS
7.1. CONTROL PANEL
7.1.1 DESCRI PTI ON OF THE CONTROL PANEL
7.1.2 DESCRI PTI ON SYMBOLS MASK
ON-OFF
With the appliance OFF, if pressed
it allows the former to be switched
on
With appliance ON, if it is pressed for
a prolonged period, allows switch-off
with warning on the display of the
function in progress (switch-off)
AUX
With single press, ON-OFF for
switching cell light on (where
envisioned)
ENTER
When pressed, the date, time and
temperature probes can be displayed
and values con
fi rmed
When pressed for a prolonged period
of time, the air recirculation fan can
be activated/ deactivated
MENU
Allows to enter the “menu” mask, in
order to choose one of the functions
available (par. 7.3.2) and to change
program (par. 7.3.6)
When pressed for a prolonged period
of time it allows to change the
programs set values (par. 7.3.6b)
Allows to decrease the value or
change menu
I n normal functioning mode, with
program started, displays the date
and time of seasoning
With prolonged pressing it zeroes the
time, starting the seasoning cycle
from phase 1
Allows to increase the value or
change menu
I n normal functioning mode, with
program started, displays the date
and time of seasoning
With prolonged pressing, blocks the
keyboard, the
s
symbol appears on
the display
LCD Display
for information
and service
LED display
to display the
temperature
Temperature display symbol
With associated LED on, indicates
that the compressor is running
With associated LED on, indicates
that there is an alarm in progress
With associated LED on, indicates
that the fans of the cell are running
With associated LED on
intermittently, indicates that the
defrosting is in progress
I ndicates the infrared serial
communication port
AUX
MENU
ENTER