Dismantle the acrylic pane of the canopy or of the lateral
part.
lter pane cover (1), swing it out (2)
Carefully and with both hands, press the
until the upper springs release the pane (5). Take the pane
out from above (6).
After cleaning the pane, mount it again in reverse order.
Operation and Service megaSun 5600
The facial tanners are equipped with an additional safety
function. Behind each of the
lter panes there is a safety switch
that switches off the burner in the case of a missing or broken
pane.
Do not operate the tanning system with a defective filter pane.
Carry out regular visual inspections!
Filter panes have to be replaced only by those of the same type!
The filter panes may be dismantled and replaced by trained
lter panes (see below), clean them with a
standard cleaning agent for glass and a soft cloth or chamois.