53
Table 13-6
Information requirements for heat pump space heaters and heat pump combination heater
s
Model(s):
KEM-90 DNS3
Air-to-water heat pump:
[yes]
Water-to-water heat pump:
[yes/no]
Brine-to-water heat pump:
[yes/no]
Low-temperature heat pump:
[yes/no]
Equipped with a supplementary heater:
[yes/no]
Heat pump combination heater:
[yes/no]
For low-temperature heat pumps, parameters shall be declared for low-temperature application.
Otherwise, parameters shall be declared for medium-temperature application. Parameters shall be declared for average climate conditions.
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated heat output
(3)
at Tdesignh = -10 (-11)°C
Prated
= Pdesignh
66.3
kW
Seasonal space heating energy efficiency
η
s
157
%
Seasonal coefficient of performance
SCOP
3.99
–
Active mode coef. of performance
SCOP
on
X.XX
–
Net seasonal coef. of performance
SCOP
net
X.XX
–
T
j
= – 7°C
Pdh
58.7
kW
T
j
= – 7°C
COPd
2.49
–
T
j
= + 2°C
Pdh
35.9
kW
T
j
= + 2°C
COPd
3.78
–
T
j
= + 7°C
Pdh
28.2
kW
T
j
= + 7°C
COPd
5.46
–
T
j
= + 12°C
Pdh
33.0
kW
T
j
= + 12°C
COPd
7.02
–
T
j
= bivalent temperature
Pdh
58.7
kW
T
j
= bivalent temperature
COPd
2.49
–
T
j
= operation limit temperature
Pdh
65.2
kW
T
j
= operation limit temperature
COPd
2.13
–
For air-to-water heat pumps:
T
j
= – 15°C (if TOL < – 20°C)
Pdh
x,x
kW
For air-to-water heat pumps:
T
j
= – 15°C (if TOL < – 20°C)
COPd
x,xx
–
Bivalent temperature
(m2°C)
Tbiv
-7
°C
For air-to-water HP: Operation limit tem-
perature (maximum -7°C)
TOL
-10
°C
Cycling interval capacity for heating at
T
j
= -7°C
Pcych
x,x
kW
Heating water
operating limit temperature
WTOL
x
°C
Degradation coefficient
(4)
at T
j
= -7°C
Cdh
x,xx
—
Cycling interval efficiency
at T
j
= +7°C
COPcyc
x,xx
–
Cycling interval capacity for heating at
T
j
= +2°C
Pcych
x,x
kW
Cycling interval efficiency
at T
j
= +12°C
COPcyc
x,xx
–
Degradation coefficient
(4)
at T
j
= +2°C
Cdh
x,xx
—
Cycling interval capacity for heating at
T
j
= +7°C
Pcych
x,x
kW
Cycling interval efficiency
at T
j
= +7°C
COPcyc
x,xx
–
Degradation coefficient
(4)
at T
j
= +7°C
Cdh
x,xx
—
Cycling interval efficiency
at T
j
= +12°C
COPcyc
x,xx
–
Cycling interval capacity for heating at
T
j
= +12°C
Pcych
x,x
kW
Degradation coefficient
(4)
at T
j
= +12°C
Cdh
x,xx
—
Power consumption in modes other than active mode
Supplementary heater (to be declared even if not provided in the unit)
Off mode
P
OFF
0.04
kW
Rated heat output (3)
Psup
= sup (Tj)
x,x
kW
Thermostat-off mode(heating)
P
TO
0.11
kW
Standby mode
P
SB
0.04
kW
Type of energy input
Crankcase heater mode
P
CK
0.04
kW
Other items
Outdoor heat exchanger
Capacity control
fixed/variable
variable
For air-to-water HP: Rated air flow rate
Q
airsource
38000
m
3
/h
Sound power level, indoors
L
WA
x
dB(A)
For water-to-water: Rated water flow rate
Q
watersource
x
m
3
/h
Sound power level, outdoors
L
WA
89
dB(A)
For brine-to-water: Rated brine flow rate
Q
brinesource
x
m
3
/h
Contact details
Name and address of the manufacturer or its authorised representative.
(1) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat
output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(2) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.