background image

  

 

Running Cost USD 

CONTENTS 

PAGE 

E-heater 

Gas Burner 

HPWH 

BASIC OPERATION PRINCIPLE.............................................................

.

.

...

SAFETY INFORMATION.................................................

..

.....................

.

....

..

BEFORE INSTALLATION.................................................................

..

........

....

INSTALLATION.................................................................................

..............

TRIAL-RUNNING............................................................................

....

...

.......

10 

OPERATION ..............................................................................

.......

.......

.

.

.

...12 

TROUBLE SHOOTING............................................................................

....

.

.

16 

MAINTENANCE..................................................................................

.....

...

.

. 18 

SPECIFICATIONS............................................................................

......

....

.

... 19 

Fig.0-1 

NOTE 

Above calculation is based on the ideal condition, the final  

cost bill will be different caused by the actual running  

conditions, such as running period, ambient temperature, etc. 

1.   SAFETY INFORMATION 

Please read thoroughly all of the instrucitons before installing or  
operating the unit.  

Following safety symbol is very important, always read and obey all  
safety symbol: 

0. BASIC OPERATION PRINCIPLE 

You may be injured if you don't obey  

CAUTION 

As we know with our experience, the natural flow of heat, which  
moves from a higher to a lower temperature source. the heat  
pump can transfer heat from a lower temperature source to a  
higher temperature source with high efficiency. 

instructions. 

You may be killed or seriously injured  

if you don't obey instructions. 

WARNING 

The advantage of a heat pump water heater is that it can supply 
more heat energy, normally 3 times than input electricity power 
by extracting the heat from ambient atmosphere in a free  
charge way to Sanitary Hot Water, compare to the traditional  
water heater, such as electric water heater or gas burner water  
heater, their efficiency is normally less than 1, which means it  
will dramatically cut off the bill of family daily SHW by the  
application of heat pump water heater, following data will show  
more details. 

You may be killed or seriously injured 

DANGER 

immediately if you don't obey instructions. 

WARNING 

The unit must be earthed effectively. 

A creepage breaker must be installed adjacent to the power  
supply. 

Power consumption comparison under the same condition to heat 1  

ton water from 15˚C to 55˚C 
The equivalent heat load Q=CM(T1-T2)=1(kCal/kg*

ć

)  

X1000(kg)*(55-15)

˄

ć

˅

=40000kCal=46.67kW*h 

Do not remove, cover or deface any permanent instructions,  
lables, or the data label from either the outside of the unit or  
inside of unit panels. 

Ask qualified person to perform the installation of this unit in 

accordance with local national regulations and this manual. 

Improper installation may result in water leakage, electric 

shock or fire. 

Table0-1 

HPWH 

Gas Burner 

Gas 

E-heater 

Energy 

Resource 

Air,Electricity 

Electricity 

Ask qualified person for relocating, repairing and maintaining 

the unit instead of doing by yourself. 

Improper installation may result in water leakage, electric 

shock or fire. 

Transfer Factor    

860kCal/KW*h      24000kCal/mϢ     860kCal/kW*h 

Average 

Efficiency 

(W/W) 

3.5 

0.8 

0.95 

Electric connection work should obey the instructions of local 

power company, local electric utility and this manual. 

Energy 

Consumption 

Never use the wire and fuse with wrong rated current, 

otherwise unit may break down and cause fire furthermore. 

13.33kW*h 

2.08mϢ 

49.13 kW*h 

Unit Cost 

0.09 USD/kW*h     2.84 USD/mϢ    0.09 USD/kW*h 

Do not insert fingers, rods or other objects into the air inlet or 

outlet. 

When the fan is rotating at high speed, it will cause injury. 

Running Cost 

USD 

1.2 

5.9 

4.42 

Never use a flammable spray such as hair spray, lacquer 

paint near the unit. 

It may cause a fire. 

Installation & Owner‘s Manual 

Summary of Contents for COMPAK KHP 15/190 ACS1

Page 1: ...S MANUAL ALL IN ONE Type Air source Heat Pump Water Heater COMPAK KHP 15 190 ACS1 Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it fo...

Page 2: ...MD14IU 029DW 202000172619...

Page 3: ...being The wiring must be performed by professional technicians in accordance with national wiring regulations and this circuit diagram An all pole disconnection device which has at least 3mm separatio...

Page 4: ...Water Outlet Cover Electric Heater Electric Heater Water Inlet Drain Pipe When ordering repair parts please always give the following information 1 Model serial and product number 2 Parts name NOTE Al...

Page 5: ...ta will show more details You may be killed or seriously injured DANGER immediately if you don t obey instructions WARNING The unit must be earthed effectively A creepage breaker must be installed adj...

Page 6: ...water condensation Drain pipe for water condensation Before cleaning be sure to stop the operation and turn the breaker off or pull out the power plug Otherwise an electric shock and injury may be cau...

Page 7: ...Hot spring area where corrosive gases exist e g sulphide gas Factories where the power voltage fluctuates seriously Inside a car or cabin The water heater must be located in a space 15m and must have...

Page 8: ...using the tank When water flow smoothly out from water outlet pipe tap water outlet the tank is full turn off all valves and check pipeline to make sure there is no any leakage CAUTION 4 If the inlet...

Page 9: ...could charge fresh air into room 2 Air inlet without duct air outlet connects to duct A 5m 4 Duct Description A Air outlet Table3 1 Air inlet Round duct Rectangle duct Duct Dimension mm 160 160X160 2...

Page 10: ...It is recommended to install the unit in the indoor space it is not allow to install the unit at the rainy space Fig 3 8 D Rain Filter Owner should install the filter by self and the mesh size is abou...

Page 11: ...Electric Heater Item Content Fan capacity Terminal base Transformer Connected wires inside of the tank Zero phase electricity mutual inductor AC mutual inductor Relay connecting wires Relay Without D...

Page 12: ...ion Solar Input 300L ON OFF SW2 Factory Setting for 190L 300L Model Selection High Pressure Switch Transformer Panel Display Panel Display T5L Lower T5U Upper T3 Evaporator T4 Ambient Th Comp Tp Comp...

Page 13: ...ration 1 GND Wiring size and connections comply with all local applicable codes and the requirements of this manual Power Cable with Creepage Breaker Water heater and electrical supply are properly gr...

Page 14: ...installation 8 Sufficient inlet water pressure between 0 15MPa and 0 65MPa Water out Fig 4 1 4 2 2 About Running CAUTION 1 System Structure Figure Unit has two kinds of heat sources heat pump compress...

Page 15: ...se manually activate E heater Restart After a Long Term Stop When the unit is restarted after a long term stop trail running included it is normal that outlet water is unclean Keep the tap on and the...

Page 16: ...pressor Last error code ON OFF 8 Previous 1st error or protection code 9 Fig 5 1 Previous 2nd t error or protection code 10 11 5 2 Display Explanation Software number SET SET CLOCK DAY 1 2 ON 3 4 ON 5...

Page 17: ...s celsius will be lightened will show celsius degree If setting temperature unit as Fahrenheit will be lightened will show Fahrenheit degree Press for 10sec it will change between and No Icon Descript...

Page 18: ...ally ON 1 The moment of Manually ON has priority 2 The moment of Timer OFF has priority Set the hour value of timer Confirm the hour value of timer Then the minute value of timer will flash slowly CAN...

Page 19: ...ess button disinfect clock setting Then icon flash and icon will be lightened for 3sec to enter will Press button for and the hour value of clock will flash slowly 1s or no button operation for 30s th...

Page 20: ...unt of hot water can be tapped A Because the upper water sensor is located on the upper 1 4 tank when tapping hot water out it means there is at least 1 4 tank of hot water available 1 Public water su...

Page 21: ...out clock menmory so it is needed to reset clock when power put on again EF Clock chip error If necessary contact a qualified person to service the unit Ed P2 E EPROM chip error Contact a qualified pe...

Page 22: ...Operate the hander of PT valve to ensure that waterways are clear Clean the air filter every month in case of any inefficiency on the heating performance In terms of the filter set in air inlet direct...

Page 23: ...adjustable Water side exchanger Inlet pipe Dia Outlet pipe Dia Drain pipe Dia PT valve Dia The test conditions Ambient temperature 15 12 C DB WB Water temperature from 15 C up to 45 C Installation Ow...