WARNING 

This unit  is required reliable 
earthing  before usage,  otherwise 
might cause  serious injuries. 

If you can't make sure that your house power supply is earthed well, please don't install the unit.  
Please have a qualified person perform the reliable earthing connection and the installation of the unit. 
Examples of a qualified person include: licensed plumbers, authorized electric company personnel, and  

authorized service personnel. 

CAUTION 

Children should be supervised to ensure that they do not play with the appliance. 
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly  
qualified person. 
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste  
separately for special treatment is necessary. 
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection  
facilities. 
Contact your local government for information regarding the collection systems available. 
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the  
groundwater and get into the food chain, damaging your health and well-being. 
The wiring must be performed by professional technicians in accordance with national wiring regulations and  
this circuit diagram. 
An all-pole disconnection device which has at least 3mm separation distance in all pole and a residual current  
device (RCD) with the rating not exceeding 30mA shall be incorporated in the fixed wiring according to the  
national rule. 
The handle of PTR valve should be pulled out once per half a year to make sure that there is no jam of the valve.  
The drainage pipe should be well insulated in order to prevent water inside pipe from freezing in cold weather. 
This appliance can be used by children aged from 8 years and above and persons with reduced physical,  
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or  
instruction concerning use of the appliance in a safe way and understand the hazards involved. Cleaning and  
user maintenance shall not be made by children without supervision. 
The discharge pipe connected to PTR is to be installed in a continuously downward direction. 
The water may drip from the discharge pipe of the pressure-relief device and that this pipe must be left open to  
the atmosphere. 
Regarding how the water heater can be drained, thanks to refer to the below paragraphs of the manual.  

Your safety is the most important thing we concerned! 

Summary of Contents for COMPAK KHP 15/190 ACS1

Page 1: ...S MANUAL ALL IN ONE Type Air source Heat Pump Water Heater COMPAK KHP 15 190 ACS1 Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it fo...

Page 2: ...MD14IU 029DW 202000172619...

Page 3: ...being The wiring must be performed by professional technicians in accordance with national wiring regulations and this circuit diagram An all pole disconnection device which has at least 3mm separatio...

Page 4: ...Water Outlet Cover Electric Heater Electric Heater Water Inlet Drain Pipe When ordering repair parts please always give the following information 1 Model serial and product number 2 Parts name NOTE Al...

Page 5: ...ta will show more details You may be killed or seriously injured DANGER immediately if you don t obey instructions WARNING The unit must be earthed effectively A creepage breaker must be installed adj...

Page 6: ...water condensation Drain pipe for water condensation Before cleaning be sure to stop the operation and turn the breaker off or pull out the power plug Otherwise an electric shock and injury may be cau...

Page 7: ...Hot spring area where corrosive gases exist e g sulphide gas Factories where the power voltage fluctuates seriously Inside a car or cabin The water heater must be located in a space 15m and must have...

Page 8: ...using the tank When water flow smoothly out from water outlet pipe tap water outlet the tank is full turn off all valves and check pipeline to make sure there is no any leakage CAUTION 4 If the inlet...

Page 9: ...could charge fresh air into room 2 Air inlet without duct air outlet connects to duct A 5m 4 Duct Description A Air outlet Table3 1 Air inlet Round duct Rectangle duct Duct Dimension mm 160 160X160 2...

Page 10: ...It is recommended to install the unit in the indoor space it is not allow to install the unit at the rainy space Fig 3 8 D Rain Filter Owner should install the filter by self and the mesh size is abou...

Page 11: ...Electric Heater Item Content Fan capacity Terminal base Transformer Connected wires inside of the tank Zero phase electricity mutual inductor AC mutual inductor Relay connecting wires Relay Without D...

Page 12: ...ion Solar Input 300L ON OFF SW2 Factory Setting for 190L 300L Model Selection High Pressure Switch Transformer Panel Display Panel Display T5L Lower T5U Upper T3 Evaporator T4 Ambient Th Comp Tp Comp...

Page 13: ...ration 1 GND Wiring size and connections comply with all local applicable codes and the requirements of this manual Power Cable with Creepage Breaker Water heater and electrical supply are properly gr...

Page 14: ...installation 8 Sufficient inlet water pressure between 0 15MPa and 0 65MPa Water out Fig 4 1 4 2 2 About Running CAUTION 1 System Structure Figure Unit has two kinds of heat sources heat pump compress...

Page 15: ...se manually activate E heater Restart After a Long Term Stop When the unit is restarted after a long term stop trail running included it is normal that outlet water is unclean Keep the tap on and the...

Page 16: ...pressor Last error code ON OFF 8 Previous 1st error or protection code 9 Fig 5 1 Previous 2nd t error or protection code 10 11 5 2 Display Explanation Software number SET SET CLOCK DAY 1 2 ON 3 4 ON 5...

Page 17: ...s celsius will be lightened will show celsius degree If setting temperature unit as Fahrenheit will be lightened will show Fahrenheit degree Press for 10sec it will change between and No Icon Descript...

Page 18: ...ally ON 1 The moment of Manually ON has priority 2 The moment of Timer OFF has priority Set the hour value of timer Confirm the hour value of timer Then the minute value of timer will flash slowly CAN...

Page 19: ...ess button disinfect clock setting Then icon flash and icon will be lightened for 3sec to enter will Press button for and the hour value of clock will flash slowly 1s or no button operation for 30s th...

Page 20: ...unt of hot water can be tapped A Because the upper water sensor is located on the upper 1 4 tank when tapping hot water out it means there is at least 1 4 tank of hot water available 1 Public water su...

Page 21: ...out clock menmory so it is needed to reset clock when power put on again EF Clock chip error If necessary contact a qualified person to service the unit Ed P2 E EPROM chip error Contact a qualified pe...

Page 22: ...Operate the hander of PT valve to ensure that waterways are clear Clean the air filter every month in case of any inefficiency on the heating performance In terms of the filter set in air inlet direct...

Page 23: ...adjustable Water side exchanger Inlet pipe Dia Outlet pipe Dia Drain pipe Dia PT valve Dia The test conditions Ambient temperature 15 12 C DB WB Water temperature from 15 C up to 45 C Installation Ow...

Page 24: ......

Reviews: