background image

  

 

No 

Icon 

Description 

No 

Icon 

Description 

E-heater: 

Timer 

       will be lightened if e-heater is activated,  
otherwise        will be extinguished. 
If e-heater is automatically activated by unit,      
will be lightened; 

There are six timers can be set. 

If anyone of them has been set,                

will lighten the corresponding one when  

screen is unlocked

˗

 

Ļ

 

If e-heater is manually activated,        will flash  
with 0.5Hz frequency. 
When setting e-heater manually ON/OFF,        
will flash with 2 Hz frequency. 

 

If there is none of timers has been set, it will  

keep extinguished. 

If timer is being set,                       will flash the  

corresponding one with 2Hz frequency as  

well lighten the timer which has been set. 

Disinfect: 
     will be lightened when the unit is under  
disinfect mode, otherwise     will be extinguished. 
     will be lightened if disinfect mode is automati- 
cally activated by unit; 
     will flash with 0.5Hz frequency, if disinfect  
mode is manually activated; 

Clock and clock setting 

           shows the clock. 

 

Whenever there is any setting for clock,              

                will be lightened. 

ļ

 

Ľ

 

     will flash with 2Hz frequency when setting  
disinfect mode or setting disinfect timer. 

ķ

 

ĸ

 

Ĺ

 

High temp. Alarm 
If setting water temp. is higher than 50

ć

ˈ

 

        will be lightened, otherwise         will be  

extinguished. 

Ļ

 

ĺ

 

Alarm: 

When unit is under protection/error,      will flash  
with 5Hz frequency as well as buzzer will sound  
3 times every 1 minute until protection/error  
eliminated or press             for 1 second. 

ľ

 

Ŀ

 

ļ

 

Ľ

 

ľ

 

Ŀ

 

Lock: 
If button is locked,       will be lightened,  
otherwise      will be extinguished. 

Fig.5-3 

Any  press  of   button  is  effective   only  under  button   and  display  

unlocked state. 

Table5-2 

Temperature unit 

If setting temperature unit as celsius,      will be  
lightened,          will show celsius degree; 
If setting temperature unit as Fahrenheit,      will  
be lightened,           will  show Fahrenheit degree. 
Press             for 10sec, it will change between 
and      . 

ŀ

 

 

No. 

Icon 

Description 

Manually turn E-heater ON 
If E-heater is OFF, follow these steps below to 

manually turn it on. 

Invalid 

Icon 

will flash. 

If button is under lock mode, press any button  
except unlock button,           will be lightened. 

Invalid 

Confirm manually turning E-heater on, 
then E-heater is activated to heat up water 
to the target temperature. After that, if 
need manually turn E-heater on again, 
please repeat these steps. 

Invalid 

           

 

         will be lightened if screen is unlocked. 
It shows water temperature on normal; 
It shows remaining vacation days on vacation; 
It shows setting temperature on setting; 
It shows unit setting/running parameters,  
error/protection code on querying. 

If E-heater is already ON, Press 

will lead 

 

to show invalid icon 

Long pressing the 

on the display. 

Invalid 

button for 10s then  can 

shift to  set the  temperature display unit  from "F"  to 

"C" or  from "C"  to  "F". The  default is  "C"(when it's 

shifted  to  display "F",  it  still  will  display  "C" while 

querying). 

Reserved 

Setting 

 

INCREASE 

If screen is unlocked, corresponding value will 

increase by pressing 

● When setting temperature, press 

more than 

1s, Temperature value will be increased continu- 

ously; 

14.1 

         will be lightened when setting water  
temperature or setting days for vacation. 

           

● When Setting clock/timer, press 

more than 

1s, Clock/timer value will be increased continuously; 

Date setting 

● When setting vacation days, press 

more 

will be lightened when setting days for 

vacation; 

than 1s, day value will be increased continuously; 

14.2 

On querying, check items will page up by pressing 

 

        will be lightened when on vacation. 

Installation & Owner‘s Manual 

13 

Summary of Contents for COMPAK KHP 15/190 ACS1

Page 1: ...S MANUAL ALL IN ONE Type Air source Heat Pump Water Heater COMPAK KHP 15 190 ACS1 Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it fo...

Page 2: ...MD14IU 029DW 202000172619...

Page 3: ...being The wiring must be performed by professional technicians in accordance with national wiring regulations and this circuit diagram An all pole disconnection device which has at least 3mm separatio...

Page 4: ...Water Outlet Cover Electric Heater Electric Heater Water Inlet Drain Pipe When ordering repair parts please always give the following information 1 Model serial and product number 2 Parts name NOTE Al...

Page 5: ...ta will show more details You may be killed or seriously injured DANGER immediately if you don t obey instructions WARNING The unit must be earthed effectively A creepage breaker must be installed adj...

Page 6: ...water condensation Drain pipe for water condensation Before cleaning be sure to stop the operation and turn the breaker off or pull out the power plug Otherwise an electric shock and injury may be cau...

Page 7: ...Hot spring area where corrosive gases exist e g sulphide gas Factories where the power voltage fluctuates seriously Inside a car or cabin The water heater must be located in a space 15m and must have...

Page 8: ...using the tank When water flow smoothly out from water outlet pipe tap water outlet the tank is full turn off all valves and check pipeline to make sure there is no any leakage CAUTION 4 If the inlet...

Page 9: ...could charge fresh air into room 2 Air inlet without duct air outlet connects to duct A 5m 4 Duct Description A Air outlet Table3 1 Air inlet Round duct Rectangle duct Duct Dimension mm 160 160X160 2...

Page 10: ...It is recommended to install the unit in the indoor space it is not allow to install the unit at the rainy space Fig 3 8 D Rain Filter Owner should install the filter by self and the mesh size is abou...

Page 11: ...Electric Heater Item Content Fan capacity Terminal base Transformer Connected wires inside of the tank Zero phase electricity mutual inductor AC mutual inductor Relay connecting wires Relay Without D...

Page 12: ...ion Solar Input 300L ON OFF SW2 Factory Setting for 190L 300L Model Selection High Pressure Switch Transformer Panel Display Panel Display T5L Lower T5U Upper T3 Evaporator T4 Ambient Th Comp Tp Comp...

Page 13: ...ration 1 GND Wiring size and connections comply with all local applicable codes and the requirements of this manual Power Cable with Creepage Breaker Water heater and electrical supply are properly gr...

Page 14: ...installation 8 Sufficient inlet water pressure between 0 15MPa and 0 65MPa Water out Fig 4 1 4 2 2 About Running CAUTION 1 System Structure Figure Unit has two kinds of heat sources heat pump compress...

Page 15: ...se manually activate E heater Restart After a Long Term Stop When the unit is restarted after a long term stop trail running included it is normal that outlet water is unclean Keep the tap on and the...

Page 16: ...pressor Last error code ON OFF 8 Previous 1st error or protection code 9 Fig 5 1 Previous 2nd t error or protection code 10 11 5 2 Display Explanation Software number SET SET CLOCK DAY 1 2 ON 3 4 ON 5...

Page 17: ...s celsius will be lightened will show celsius degree If setting temperature unit as Fahrenheit will be lightened will show Fahrenheit degree Press for 10sec it will change between and No Icon Descript...

Page 18: ...ally ON 1 The moment of Manually ON has priority 2 The moment of Timer OFF has priority Set the hour value of timer Confirm the hour value of timer Then the minute value of timer will flash slowly CAN...

Page 19: ...ess button disinfect clock setting Then icon flash and icon will be lightened for 3sec to enter will Press button for and the hour value of clock will flash slowly 1s or no button operation for 30s th...

Page 20: ...unt of hot water can be tapped A Because the upper water sensor is located on the upper 1 4 tank when tapping hot water out it means there is at least 1 4 tank of hot water available 1 Public water su...

Page 21: ...out clock menmory so it is needed to reset clock when power put on again EF Clock chip error If necessary contact a qualified person to service the unit Ed P2 E EPROM chip error Contact a qualified pe...

Page 22: ...Operate the hander of PT valve to ensure that waterways are clear Clean the air filter every month in case of any inefficiency on the heating performance In terms of the filter set in air inlet direct...

Page 23: ...adjustable Water side exchanger Inlet pipe Dia Outlet pipe Dia Drain pipe Dia PT valve Dia The test conditions Ambient temperature 15 12 C DB WB Water temperature from 15 C up to 45 C Installation Ow...

Page 24: ......

Reviews: