background image

  

 

6.   TROUBLE SHOOTING 

6.1   Non-error tips 

6.3  When Error happened 

1)  If some normal errors happen, unit will automatically shift to E- 

heater for emergent SHW supply, please contact qualified staff to  

repair.  

Q: Why compressor can't start immediately after setting? 

A: Unit will wait for 3 min to balance the pressure of system before  

    start compressor again, it's a self protection logic of unit. 

2)  If  some  sever  error  happen,  unit  will  not  start,  please  contact  

qualified staff to repair.  

Q: Why sometimes the temperature shown on the display panel 

    decreased while unit is running? 

A: When the upper tank temperature is much higher than the bottom  

    part, upper part hot water will be mixed by the bottom cold water 

    which is continually flow from inlet tap water so that will decrease 

    the upper part temperature. 

3)  If some errors happen, the buzzer will buzz 3 times every other  

minute and the      will flash fast. Press             for 1 sec to stop  

the buzzer but the alarm icon will keep glittering. 

6.4  Error phenomenon shooting 

Q:Why sometimes the temperature shown on the display decreased 

    but unit still keep closed? 

Table6-1 

A: to avoid unit ON/OFF frequently, unit will activate heat source only  

    when bottom tank temperature is lower than setting temperature 

    for at least 5 ºC. 

Error  
phenomenon 

Possible reason 

solution 

Q:Why sometimes the temperature shown on the display will 

    decreased dramatically? 

A: Because tank is pressure-bearable type, if there is massive hot 

    demand, hot water will quickly tapped out from upper part of tank 

    as well as cold water will quickly tapped into bottom part of tank, 

    if the cold water surface emerge the upper temperature sensor, 

    temperature shown on the display will decreased dramatically. 

1. Bad connection  

between power supply  
plug and socket; 

Cold water  

1. Plug in; 

tapped out and   

2. 

Setting
                                                           
water  

2. Setting water temp.  
higher; 
3. Contact service center. 

display screen  

temperature too low; 

extinguished 

3. Temp. sensor broken; 

PCB of indicator broken. 

Q:Why sometimes the temperature shown on the display is 

    decreased a lot, but there is still amount of  hot water can be 

    tapped? 

A:Because the upper water sensor is located on the upper 1/4 tank, 

    when tapping hot water out, it means there is at least 1/4 tank of hot 

    water available.  

1.Public water supply  

ceased; 

1. Waiting for public water  

supply recover; 

No hot water  
tapped out 

2.Cold water inlet pressure   2. Waiting for inlet water  

too low (<0.15 MPa); 

Q:Why sometimes unit shows "LA" on display ? 

pressure increase; 

A:  The  heat  pump  available  running  ambient  range  is  -7-43

ć

if  

ambient  temperature  is  out   of  range,  system  will  show   above- 

mentioned signal to let user notice it. 

3.Cold water inlet valve  

3. Open water inlet valve. 

closed. 

Hydraulic pipeline joints  
are not sealed well.  

Q: Why something there is nothing shown on the display? 

A: To maintain display screen lifespan within along term, when there 

 is no button operation for 30 sec, it will extinguish the display 

 except the LED indicator. 

Water leakage 

Check and reseal all  
joints. 

Q: Why sometimes the buttons are unavailable? 

A: if there is no operation on panel for 1 min, unit will lock the panel,  

    shows "   ", to unlock the panel, please press the "ENTER" button 

    for 3 seconds. 

Q: Why sometimes there is some water flowed from drainage pipe of 

     PT valve? 

A: Because the tank is pressure-bearable one, when water is heated 

    inside the tank, water will expand, so the pressure inside of tank 

    will increase, if pressure goes up more than 1.0Mpa, PT valve will 

    activate to relief the pressure and hot water drop will be discharged 

    correspondingly. If water drop is continually discharged from PT 

    valve drainage pipe, it is abnormal, please contact qualified stuff to 

    repair. 

6.2  Something about self-protection of unit 

1)  When the self-protection happens, the system will be stopped  

and start self-check, and restart when the protection resolved. 

2)  When the self-protection happens, the buzzer will buzz in every  

other minute, the      will flash and error code will be shown at  

water temperature indicator. Press               button for 1sec to  

stop buzz, but the      and error code does not disappear until  

protection resolved. 

3)  In the following circumstance, self-protection may happen: 

Air inlet or outlet is blocked; 

The evaporator is covered with too much dust; 

Incorrect power supply(exceeding the range of 220-240V). 

Installation & Owner‘s Manual 

16 

Summary of Contents for COMPAK KHP 15/190 ACS1

Page 1: ...S MANUAL ALL IN ONE Type Air source Heat Pump Water Heater COMPAK KHP 15 190 ACS1 Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it fo...

Page 2: ...MD14IU 029DW 202000172619...

Page 3: ...being The wiring must be performed by professional technicians in accordance with national wiring regulations and this circuit diagram An all pole disconnection device which has at least 3mm separatio...

Page 4: ...Water Outlet Cover Electric Heater Electric Heater Water Inlet Drain Pipe When ordering repair parts please always give the following information 1 Model serial and product number 2 Parts name NOTE Al...

Page 5: ...ta will show more details You may be killed or seriously injured DANGER immediately if you don t obey instructions WARNING The unit must be earthed effectively A creepage breaker must be installed adj...

Page 6: ...water condensation Drain pipe for water condensation Before cleaning be sure to stop the operation and turn the breaker off or pull out the power plug Otherwise an electric shock and injury may be cau...

Page 7: ...Hot spring area where corrosive gases exist e g sulphide gas Factories where the power voltage fluctuates seriously Inside a car or cabin The water heater must be located in a space 15m and must have...

Page 8: ...using the tank When water flow smoothly out from water outlet pipe tap water outlet the tank is full turn off all valves and check pipeline to make sure there is no any leakage CAUTION 4 If the inlet...

Page 9: ...could charge fresh air into room 2 Air inlet without duct air outlet connects to duct A 5m 4 Duct Description A Air outlet Table3 1 Air inlet Round duct Rectangle duct Duct Dimension mm 160 160X160 2...

Page 10: ...It is recommended to install the unit in the indoor space it is not allow to install the unit at the rainy space Fig 3 8 D Rain Filter Owner should install the filter by self and the mesh size is abou...

Page 11: ...Electric Heater Item Content Fan capacity Terminal base Transformer Connected wires inside of the tank Zero phase electricity mutual inductor AC mutual inductor Relay connecting wires Relay Without D...

Page 12: ...ion Solar Input 300L ON OFF SW2 Factory Setting for 190L 300L Model Selection High Pressure Switch Transformer Panel Display Panel Display T5L Lower T5U Upper T3 Evaporator T4 Ambient Th Comp Tp Comp...

Page 13: ...ration 1 GND Wiring size and connections comply with all local applicable codes and the requirements of this manual Power Cable with Creepage Breaker Water heater and electrical supply are properly gr...

Page 14: ...installation 8 Sufficient inlet water pressure between 0 15MPa and 0 65MPa Water out Fig 4 1 4 2 2 About Running CAUTION 1 System Structure Figure Unit has two kinds of heat sources heat pump compress...

Page 15: ...se manually activate E heater Restart After a Long Term Stop When the unit is restarted after a long term stop trail running included it is normal that outlet water is unclean Keep the tap on and the...

Page 16: ...pressor Last error code ON OFF 8 Previous 1st error or protection code 9 Fig 5 1 Previous 2nd t error or protection code 10 11 5 2 Display Explanation Software number SET SET CLOCK DAY 1 2 ON 3 4 ON 5...

Page 17: ...s celsius will be lightened will show celsius degree If setting temperature unit as Fahrenheit will be lightened will show Fahrenheit degree Press for 10sec it will change between and No Icon Descript...

Page 18: ...ally ON 1 The moment of Manually ON has priority 2 The moment of Timer OFF has priority Set the hour value of timer Confirm the hour value of timer Then the minute value of timer will flash slowly CAN...

Page 19: ...ess button disinfect clock setting Then icon flash and icon will be lightened for 3sec to enter will Press button for and the hour value of clock will flash slowly 1s or no button operation for 30s th...

Page 20: ...unt of hot water can be tapped A Because the upper water sensor is located on the upper 1 4 tank when tapping hot water out it means there is at least 1 4 tank of hot water available 1 Public water su...

Page 21: ...out clock menmory so it is needed to reset clock when power put on again EF Clock chip error If necessary contact a qualified person to service the unit Ed P2 E EPROM chip error Contact a qualified pe...

Page 22: ...Operate the hander of PT valve to ensure that waterways are clear Clean the air filter every month in case of any inefficiency on the heating performance In terms of the filter set in air inlet direct...

Page 23: ...adjustable Water side exchanger Inlet pipe Dia Outlet pipe Dia Drain pipe Dia PT valve Dia The test conditions Ambient temperature 15 12 C DB WB Water temperature from 15 C up to 45 C Installation Ow...

Page 24: ......

Reviews: