簡易維修
SIMPLE REPAIR
線圈阻抗:
0.8
Ω±15
﹪/
相
Winding Resistance:0.8
Ω±15
﹪
/ Phase
A
:控制系統輸出功能檢測:
先按住 ”載入針數鍵” 然後開機,即可進入系統輸出功能檢測。
檢測內容:
LED
燈號、步進馬達正反轉、
LCM
顯示面板、段數顯示器、
蜂鳴器、電磁閥組
Enter the output function in system to examine by keeping pressing the
“stitch loading key” and then start the machine.
Examination: LED light, stepping motor driver reversible rotation, LCM display
panel, section display, buzzer, and solenoid comb.
Examine the output function in control system:
B
:控制器輸入功能檢測:
Examine the controller input function:
先按住 ”切刀鍵” 然後開機,即可進入系統輸入功能檢測。
檢測內容:人機操作盒所有按鍵。(
1
)安全開關、(
2
)切刀開關、
(
3
)換段開關、(
4
)回踩開關
畫面顯示:
The panel shows
Enter the input function in system to examine by keeping pressing
“trimmer key” and then start the machine.
Examination: All the keys on the machine box, (1)safety lock switch ,
(2)trimmer switch , (3)section exchange switch ,
and (4)back pedal switch .
C
:控制系統回復出廠設定值:
Revert the control system to the pre-programmed setting value:
先按住 ”取消鍵” 然後開機,即可回復出廠設定值。
PS
:原先的循環縫設定都會被清除。
Revert to the pre-programmed value by keeping pressing “cancel key”
and then start the machine.
P.S.: The initial circulation sewing setting would be eliminated.
五相步進馬達檢測:
Examine the 5-phase stepping motor
Summary of Contents for Siruba LF-D6
Page 1: ...LF D6 使用說明書與零件圖 INSTRUCTION BOOK PARTS LIST ...
Page 2: ......
Page 14: ... 10 接管圖 WIRINGDIAGRAM ...
Page 33: ... 29 ...
Page 34: ... 30 ...
Page 35: ... 31 ...
Page 36: ... 32 ...
Page 37: ... 33 ...
Page 38: ... 34 ...
Page 39: ... 35 桌板圖 TABLE CUT OUT OF 747S T5 ...
Page 40: ......
Page 41: ......