20 en | Operation
LE80 Radio Receiver
LE80_UM_EN_V1.1_2021.12
User Manual
TeleAlarm
6
Operation
6.1
Standby mode
The LE80 Radio Receiver enters standby mode when the
power supply is connected. Both relays are off. See
Section 5.2.1 Reduced radio range, Page 15.
6.1.1
Standby with no transmitter programmed
Device behavior
–
LED 1 stays permanently green.
–
LED 2 blinks 3 times blue every 10 seconds.
6.1.2
Standby with at least one transmitter
programmed
Device behavior
–
LED 1 stays permanently green.
–
LED 2 stays permanently off.
6.2
Normal mode (modes 1 and 2)
6.2.1
Activation of a transmitter in normal mode
Device behavior
–
LED 1 stays permanently green.
When a matched transmitter is activated:
–
LED 2 lights up permanently red for 2 seconds.
–
Relay 1 switches on for 2 seconds.
–
Relay 2 stays off.
If the same or another matched transmitter is activated
within 2 seconds, the alarm will be retriggered and relay 2
will be activated for another 2 seconds (without release).
Device behavior when a transmitter has a low battery
–
LED 1 stays permanently green.
When the transmitter is activated:
–
LED 2 blinks red twice for 2 seconds, then blinks once
every 10 seconds.