1. Product Flow
: Product flow is expressed in Gallons Per Hour (GPH) or Liters Per Hour (LPH), by
this equation:
3600 ÷ time in seconds x quantity of water in gallons or liters = GPH or LPH
There are 3600 seconds in an hour.
Example: It took 3 minutes and 35 seconds to collect 1 gallon of product water.
3600 ÷ 215 x 1 =
16.74 GPH
(3 minutes, 35 seconds is 215 seconds)
Example: It took 2 minutes and 25 seconds to collect 2.5 liters of product water.
3600 ÷ 145 x 2.5 =
62.07 LPH
(2 minutes, 25 seconds is 145 seconds)
2. Total Flow or Feed Flow:
Feed flow or total flow (brine + product) is expressed in Gallons Per
Minute (GPM) or Liters Per Minute (LPM) , by this equation:
60 ÷ time in seconds x quantity of water in gallons or liters = GPM or LPM
Example: It took 1 minute and thirty
-
seven seconds to collect 5 gallons of total flow.
60 ÷ 97 x 5 =
3.09 GPM
(1 minute, 37 seconds is 97 seconds)
Example: It took 53 seconds to collect 12 liters of total flow.
60 ÷ 53 x 12 =
13.58 LPM
3. Recovery Rate:
Product Flow ÷ Total Flow = Recovery Rate %
Example: 6.5 GPH product flow =
.063 or 6.3%
1.7 GPM total flow x 60
(you must first multiply total flow by 60 to convert from GPM to GPH)
*pressure relief valve open ½ turn
In order to make good quality product water, you need the proper amount of feed water flow, as
in the table below. Compare the product flow to the total feed flow. Product flow should be 9.0%
of total flow for a Catalina 340R. If product percentage is low, you may have an internal leak in the
Clark Pump.
For every
1
/
10
th
of a GPM feed water flow loss, we will lose about
1
/
2
gallon per hour of product
flow and the salinity will go up 100 PPM.
Low feed flow combined with low system pressures is most frequently caused by a worn pump
head.
System
AMPS
Feed
Static *
Feed Flow
Product Flow
12V
MAX
24V
MAX
Press.
Press.
Flow
MIN
MIN
Flow
Flow
MIN
MIN
PSI
bar
PSI
GPM
LPM
GPM
LPM
GPH
LPH
GPH
LPH
Catalina
≈18
20
≈ 9
10
90
-
100
6.2
-
7
25
-
30
2.8
10.6
2.7
10.2
14
52.9
13.5
51.0
Summary of Contents for Spectra Watermakers Catalina 340R
Page 2: ...2 ...
Page 4: ...4 ...
Page 6: ...6 ...
Page 8: ...8 ...
Page 14: ...14 Installation Notes ...
Page 17: ...17 ...
Page 20: ...20 ...
Page 21: ...21 John Guest Super Speedfit Fittings ...
Page 52: ...52 ...
Page 55: ...55 ...
Page 63: ...63 Parts 1 ...
Page 64: ...64 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...
Page 68: ...68 ...
Page 70: ...70 ...
Page 73: ...73 ...