![Katadyn Spectra Watermakers Catalina 340R Installation And Operating Manual Download Page 26](http://html1.mh-extra.com/html/katadyn/spectra-watermakers-catalina-340r/spectra-watermakers-catalina-340r_installation-and-operating-manual_3608509026.webp)
26
Watermakers should never be run unattended.
Tank Full
If a tank switch has been installed, the
“
Running
”
and
“
Stopped
”
lights will be
illuminated when the tank is full and the
system will stop.
Your watermaker should never be left running unattended.
WARNING
!
Optional Tank Switch
The customer supplied float switch must be connected to the
Terminals 5 & 6
labeled
Tank
Full
within the Control Box that is mounted to the inside of the Feed Pump Module
.
There is
no polarity. Remove the jumper. Connect the wires to the terminals.
Use 18/2 tinned wire or larger. Wire is not included in the installation kit.
Connect to
Terminals 5 &6
Note:
Remove
only
the jumper in terminals 5 & 6.
OR
Top
-
Mounted
Side
-
Mounted