Maintenance
General
Periodically inspect the entire system for leakage and chafing. Repair any leaks as
soon as you find them. Some crystal formation around the Clark Pump blocks is normal. Wipe
down any salt encrusted areas with a damp cloth.
Watermakers are at their best when run regularly. Biological fouling in the membrane is more
likely when a watermaker sits idle. A warm environment will cause more growth than a cold
environment. A fresh water flush every five days will greatly reduce biological growth, but may
not stop it completely. The Z
-
Ion system protects the membrane from bio
-
fouling without the
use of storage chemicals and can be flushed every 30 days for maximum effectivity.
The Seawater Strainer
The seawater strainer
’
s stainless steel element should be inspected, removed, and cleaned as
needed. Ensure that the thru
-
hull is closed before disassembly and the gasket is in place before
reassembly. When the system is put into storage, remove the strainer, rinse with fresh water,
and reassemble dry to impede corrosion. Check frequently during operation.
Prefilter Assembly
Prefilter elements must be changed frequently. The rate is solely dependent on the input water.
A 5
-
micron filter might last you a 4
-
6 weeks in clear open ocean seawater, or be ruined in 45
minutes in a dirty harbor. A vessel may be sailing through seemingly super clear water, but
cruise through a plankton bloom and the prefilter will be ruined. Filters may be cleaned
only up
to three times
each with a soft brush and water in a bucket, hung overboard overnight, or
dragged behind a vessel underway. Drying in the sun helps remove odors. However, every time
you clean off a prefilter element, sediment eventually gets forced deeper into the pleats of the
prefilter, making it ineffective after two or three cleanings.
To service the filter close the thru
-
hull, open the prefilter housing, remove the old filter, clean
out the housing bowl, and reassemble the housing with a new 5 micron filter element. Leave dry
until next startup.
Note:
Use only Spectra
-
approved filters or you may void your warranty. Occasionally, lightly
lubricate the O
-
rings with silicone grease.
Oil/Water Separator (Optional)
To install oil water separator capability, add a second filter housing UPSTREAM of the 20 and 5
micron housings. Service as you would per the instructions above.
Summary of Contents for Spectra Watermakers Catalina 340R
Page 2: ...2 ...
Page 4: ...4 ...
Page 6: ...6 ...
Page 8: ...8 ...
Page 14: ...14 Installation Notes ...
Page 17: ...17 ...
Page 20: ...20 ...
Page 21: ...21 John Guest Super Speedfit Fittings ...
Page 52: ...52 ...
Page 55: ...55 ...
Page 63: ...63 Parts 1 ...
Page 64: ...64 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...
Page 68: ...68 ...
Page 70: ...70 ...
Page 73: ...73 ...