43
Feed pump runs constantly,
will not turn off
•
Turn off manual switch on control box
•
Manual switch in ON
position on control box
Display activates, but pump
will not run
•
Loose or broken pump wire
connection
•
Tanks are full (if equipped
with tank switch). If full, Run
& Stop LED should be lit.
•
Check wiring at terminal block
inside control box
•
Check tanks–
system cannot be
started if tanks are full.
System runs, no product water
delivered to water tanks
•
Disconnected or broken
product tubing
•
3
-
Way Valve Incorrectly set
•
Check product tubing
•
Check 3
-
Way Valve position
•
Check pressure relief valve is tightly
closed.
Feed pump runs with loud
noise
•
Intake blocked
•
Air in system
•
Check thru
-
hull valve
•
Check sea strainer for leaks
•
Check fresh water flush module for
leaks
•
Re
-
prime system (restart)
Troubleshooting Catalina Remote Manual Systems
SYMPTOMS
PROBABLE CAUSE
REMEDY
High feed pressure, High Am-
perage, & Product Flow down
up to 15%
•
Colder or more saline water
•
Brine or product flow path
subject to back pressure
•
Scaled or fouled membrane
•
Normal condition
•
Confirm by routing into a bucket to
test
•
Clean Membrane
Feed Pump not running, no
noise
•
No power at feed
pump
•
DC speed controller
needs to be adjusted
•
DC speed controller
malfunction
•
Check voltage at
motor/speed controller
MTR leads
•
Adjust speed controller
per manual directions
•
Replace speed
controller
Feed pump turns on, no pressure
•
Feed pump air locked
•
Pressure relief valve open
•
Open pressure relief valve
to bleed the air, then close
to start
•
Close pressure relief valve
Low Feed Pressure, Low Am-
perage
•
Warm saltwater or brackish
water
•
Normal condition
No product flow, good brine
discharge flow,
Recovery percentage is 0 (See
Flow Test)
•
Internal leak in Clark Pump
•
While system is running, kink brine
hose to stop flow until pressure rises to
125psi (a few seconds), release hose
quickly, repeat no more than 10 times
in succession.
*NOTE: RELEASE HOSE AS SOON
AS VANE PUMP BEGINS TO LABOR
OR PERMANENT DAMGE MAY
OCCUR
•
Inspect Clark Pump Check Valves
•
Complete Service is recommended.
Contact Dealer or see Clark Pump
rebuild manual. Install Offshore Kit
Summary of Contents for Spectra Watermakers Catalina 340R
Page 2: ...2 ...
Page 4: ...4 ...
Page 6: ...6 ...
Page 8: ...8 ...
Page 14: ...14 Installation Notes ...
Page 17: ...17 ...
Page 20: ...20 ...
Page 21: ...21 John Guest Super Speedfit Fittings ...
Page 52: ...52 ...
Page 55: ...55 ...
Page 63: ...63 Parts 1 ...
Page 64: ...64 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...
Page 68: ...68 ...
Page 70: ...70 ...
Page 73: ...73 ...