45
SYMPTOMS
PROBABLE CAUSE
REMEDY
•
Check brine discharge
•
Check static pressure
(pressure with system
running and pressure relief
valve open 1/2 turn)
*Nominal Static Pressure
on CT340 is 25
-
35psi
•
Route product vented to
atmosphere. Preferred
method is freefall into top of
tank.
•
Diagnose by routing product
water into bucket and run
system
•
Clean membrane
•
Replace vacuum switch
Fault Light Illuminated
High Pressure or Vacuum Switch
•
Blocked brine discharge
•
Restriction in Clark Pump/
Membrane
•
Product line not vented,
causing back pressure
•
Fouled membrane
•
Vacuum switch faulty
Boost Pressure Vacuum Switch
•
Prefilter/Sea Strainer clogged
•
Intake restriction
•
Boost Pump not receiving 24V,
or disconnected
•
Vacuum switch faulty
•
Install new prefilters
•
Clear strainer
•
Clear obstruction
*Check black 2
-
piece
hexagon check valve
attached to boost pump/
sea strainer module
•
Check voltage at boost pump,
check wiring.
•
Replace vacuum switch
Catalina 340R Fault Alarms