![Katadyn Spectra Watermakers Catalina 340R Installation And Operating Manual Download Page 39](http://html1.mh-extra.com/html/katadyn/spectra-watermakers-catalina-340r/spectra-watermakers-catalina-340r_installation-and-operating-manual_3608509039.webp)
39
Storage Procedure
1.
Close the intake seacock.
2.
Push the
Fresh Water Flush (FWF)
button
to fresh water flush the system. Perform a second
fresh water flush in the same way.
3.
Remove the quick disconnect fitting from the brine discharge outlet of the Clark Pump, per
photo below, and replace it with the quick disconnect brine discharge service hose. Lead the
brine service hose into the bucket.
4.
Push the
FWF
button and run the feed pump until you have one gallon of fresh water in the
bucket from the brine discharge service hose, then press
Stop
.
5.
Mix 1 container of SC
-
1 storage compound with the water in the bucket. It may not dissolve
completely, which is normal, and any undissolved particles will be caught by the pre
-
filter.
6.
Remove the hose from the
“
to strainer
”
pigtail on the feed pump module and install the inlet
service hose from the service kit, per photos below. Lead
this hose into the 5 gallon (20 liter) bucket as well.
7.
Make sure the pressure relief valve on the Clark Pump is
OPEN (un
-
pressurized) by turning 1/2 turn
counterclockwise
8.
Turn on the feed pump by moving the manual control
switch on the control box to
‘
SERVICE
’.
The solution will be
drawn from the bucket with the service hose, and
returned to the bucket from the brine discharge service
hose. Circulate the storage chemical in the system for
approximately 20 minutes. Stop the feed pump by moving the switch back to the
‘
RUN
AUTO
’
position.
Clean Up
Remove the brine discharge service hose from the Clark Pump, and replace the brine discharge
hose that leads to the thru
-
hull. You may now pump the bucket dry by moving the manual
control switch on the Control Box back to
‘
SERVICE
’.
Stop the feed pump by moving the switch
back to RUN AUTO.
Remove the inlet service hose and reattach the hose from the sea strainer to the
“
To Strainer
”
pigtail on the manifold at the Feed Pump Module. Drain and clean the strainer and any filters in
the system. Reassemble dry. Leave the pressure relief valve open, since the next time you run
the system you will need to purge the storage chemicals with the system unpressurized. Turn off
the power to the system.
Connecting brine discharge
service hose
Attaching intake service hose to
the hose connecting to the sea
strainer.
Removing hose to sea strainer
from the
“
to strainer
”
pigtail.
Summary of Contents for Spectra Watermakers Catalina 340R
Page 2: ...2 ...
Page 4: ...4 ...
Page 6: ...6 ...
Page 8: ...8 ...
Page 14: ...14 Installation Notes ...
Page 17: ...17 ...
Page 20: ...20 ...
Page 21: ...21 John Guest Super Speedfit Fittings ...
Page 52: ...52 ...
Page 55: ...55 ...
Page 63: ...63 Parts 1 ...
Page 64: ...64 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...
Page 68: ...68 ...
Page 70: ...70 ...
Page 73: ...73 ...