background image

2400 – 4400 VFX DECORATIVE AERATOR

MANUAL

884170 / 2021.1.1

6

Use ropes to position the fountain in the desired location in the 

pond or lake� Anchor the ropes or secure them to the shoreline so 

that they are free of slack, but not tight� To prevent twisting of the 

unit due to motor torque, place the anchor at least 3 feet from the 

float for each foot of depth (Ex. a 6ft deep pond would require an 

anchor 18ft horizontally from the float).

Alternate Installation:

In ponds where the water level fluctuates significantly, a small 

weight may need to be suspended at the midpoint of the rope 

to take up any slack caused by a drop in water level (1 foot 

of 1’’ galvanized pipe works well). The weight should be light 

enough so that the fountain can rise as the water level rises� 

This weight can also help hide the anchoring ropes by sinking 

them further below the surface�

UNIT INSTALLATION INSTRUCTIONS

After unit is installed in the water, connect the power cord to a 

properly installed Kasco control panel (C-85, C-95, etc.) with built-in 

ground fault protection according to the instructions and electrical 

schematics included with the panel� 

Follow all local and national 

electrical codes for unit and control panel installation; consult 

a qualified electrician or service person if needed. 

The fountain is ready to be turned on and enjoyed�

Anchor rope

Secondary weight

Normal water level

Low water level

High water level

Power cord

x

Kasco power 

control box

Correct anchoring

Incorrect anchoring

Providing strain relief on the cord helps ensure that its weight 

and any strain placed on it in the water will not cause the float 

to tilt or cause damage to the unit� 

If your Kasco cord comes with a strain relief kit attached, attach 

the available link to the float-side knot in the mooring rope, as 

pictured here�

Cord Strain Relief

Back to Contents

Summary of Contents for 2400VFX

Page 1: ...FX Decorative Aerator 2400VFX 3400VFX 3400HVFX 4400VFX 4400HVFX 800 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com www kascomarine com Document number 884170 Operation Maintenance Manua...

Page 2: ...rd to either side of the float If you have a light kit make sure that the unit cord is tied to one side of the float and the light cord to the other for balance It is extremely important to test the G...

Page 3: ...conductor and or a grounding type attachment plug To reduce the risk of electrical shock be certain the unit is properly connected to the Kasco supplied control panel refer to the instructions include...

Page 4: ...210 4 1 4 split washers 7 840537 5 1 4 3 4 OD flat washer 10 251300 6 1 4 20 x 1 3 4 hex head screw 3 475630 7 Bottom screen section 3 361540 8 1 4 20 nut 3 840536 9 8 nut 6 771034 10 8 flat washer 12...

Page 5: ...with legs 2 Lock washer goes between bolt and flat washer Tighten down in 4 places 3 4 5 9 10 11 12 10 3 Turn over Bring bottom screen sections together 8 4 5 5 6 ASSEMBLY INSTRUCTIONS 4 Tighten down...

Page 6: ...by sinking them further below the surface UNIT INSTALLATION INSTRUCTIONS After unit is installed in the water connect the power cord to a properly installed Kasco control panel C 85 C 95 etc with buil...

Page 7: ...onnect switch to provide circuit protection and a disconnection means C 85 panel requires at least a 30amp protected circuit feeding the panel C 95 panel requires at least a 40 amp protected circuit f...

Page 8: ...n the ON position 2 If the GFCI tests okay restore power by pushing the RESET button back in THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND REMAINS DEPRESSED AFTER PRES...

Page 9: ...ippers to the outer ring position for the entire period that the aerator is to be turned ON i e 15min for each tripper on the 24 hour dial When the tripper is pushed to the inside the switch is in the...

Page 10: ...50 5A Prop 2400VFX 1 240595 5B Prop 3400VFX 3400HVFX 1 340595 5C Prop 4400VFX 4400HVFX 1 440600 6A Top disk 2400VFX 1 241025 6B Top disk 3400VFX 3400HVFX 1 241035 6C Top disk 4400VFX 4400HVFX 1 241045...

Page 11: ...unit upside down if it will sit for a long period of time to ensure continued oil lubrication of seals units that sit upright for many months or years have a greater likelihood of seals drying out CLE...

Page 12: ...riginal receipt and registering the equipment online at kascomarine com under the Warranty Information section Once warranty coverage has been established the unit may be sent to Kasco Marine or any K...

Page 13: ...t before the work is performed All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer Rejected equipment can be returned at the customer s expense for s...

Page 14: ...aker single phase units only Each Kasco aerator has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will start back up If you are noticing th...

Page 15: ...customer to ship and pay freight to Kasco Note Contact Information should be that of the person or company to contact for repair information Company name Contact name First name Last name Address Str...

Reviews: