background image

2400 – 4400 VFX DECORATIVE AERATOR

MANUAL

884170 / 2021.1.1

11

MAINTENANCE RECOMMENDATIONS

Under NO CIRCUMSTANCE should anyone enter the water while a fountain is operating.

The following maintenance procedures can be utilized to ensure many years of quality performance from your Kasco equipment and 

reduce the need for more costly repair work�

PROPER INSTALLATION: 

 Proper installation of Kasco equipment will include a power source with ground fault protection� The control 

panel included with the equipment has built-in ground fault protection for both the fountain and the lighting kit� Ground fault interrupters 

are a safety feature that can also alert you to electrical leaks in the equipment� It is extremely important to test the GFI upon installation 

and every month thereafter to ensure proper operation� If you have repeat, consistent trips of the ground fault device, the equipment 

should be disconnected and removed from the water� The power cord should be inspected for damage, and you should contact your 

distributor or contact Kasco Marine at 715-262-4488 or [email protected] for further instructions. A complete list of control pan

-

els can be found in the Accessories section of kascomarine�com�

OBSERVATION: 

Operating equipment should be observed on a regular basis (daily, if possible) for any reduction or variation in perfor-

mance� If a change in performance is observed, the equipment should be disconnected from power and inspected� 

WINTER STORAGE: 

In regions where there is significant freezing in the wintertime, the equipment should be removed from the water 

to protect it from the expansion pressure of ice� Aerators may keep some amount of ice open, but when water is thrust into the air it can 

make the existing ice thicker. Storage over winter is best in a location that is out of the sun and cool, but above 32° F. Store unit upside 

down if it will sit for a long period of time to ensure continued oil lubrication of seals; units that sit upright for many months or years have 

a greater likelihood of seals drying out�

CLEANING:

 Aerators should be removed from the water at least once per year (at the end of the season in cold climates) to clean 

the exterior of the system, especially the stainless-steel motor housing (can) that dissipates heat into the water� Any algae, calcium, or 

other build-up will become an insulator that blocks heat transfer and may lead to overheating and damage� In warmer regions, the unit 

should be removed and cleaned at least 2 – 3 times per year. In most cases, a power washer is sufficient if the unit and algae are still 

wet�

SEAL AND OIL REPLACEMENT: 

This is a sealed motor assembly, and seals will wear out over time (similar to brake pads on a car)� 

Replacement of the seals and a change of oil after three years may add longevity to the operation of the motor, saving you the cost of 

more expensive repairs� In warmer climates where the aerator runs for a majority of the year or greater, it is wise to replace seals more 

often�

ZINC ANODE: 

A sacrificial zinc anode is supplied on the shaft of all VFX Model aerators for protection from corrosion and electrolysis. 

The zinc anode should be updated/replaced if reduced to half the original size or if white in color� Corrosion from electrolysis is more 

commonly associated with saltwater or brackish water, but as a matter of precaution, it is important to periodically check the zinc anode 

in all installations (at least every two to three months)� 

Seal replacement and all other repair services should be performed by Kasco Marine or a Kasco-trained Authorized Repair Center� Any 

alterations or changes made to Kasco units by an unauthorized source will void the warranty� This includes tampering with the unit, 

power cord, and/or control panel. Contact Kasco Marine at 715-262-4488 or [email protected] for additional information and 

your closest Authorized Repair Center�

Back to Contents

Summary of Contents for 2400VFX

Page 1: ...FX Decorative Aerator 2400VFX 3400VFX 3400HVFX 4400VFX 4400HVFX 800 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com www kascomarine com Document number 884170 Operation Maintenance Manua...

Page 2: ...rd to either side of the float If you have a light kit make sure that the unit cord is tied to one side of the float and the light cord to the other for balance It is extremely important to test the G...

Page 3: ...conductor and or a grounding type attachment plug To reduce the risk of electrical shock be certain the unit is properly connected to the Kasco supplied control panel refer to the instructions include...

Page 4: ...210 4 1 4 split washers 7 840537 5 1 4 3 4 OD flat washer 10 251300 6 1 4 20 x 1 3 4 hex head screw 3 475630 7 Bottom screen section 3 361540 8 1 4 20 nut 3 840536 9 8 nut 6 771034 10 8 flat washer 12...

Page 5: ...with legs 2 Lock washer goes between bolt and flat washer Tighten down in 4 places 3 4 5 9 10 11 12 10 3 Turn over Bring bottom screen sections together 8 4 5 5 6 ASSEMBLY INSTRUCTIONS 4 Tighten down...

Page 6: ...by sinking them further below the surface UNIT INSTALLATION INSTRUCTIONS After unit is installed in the water connect the power cord to a properly installed Kasco control panel C 85 C 95 etc with buil...

Page 7: ...onnect switch to provide circuit protection and a disconnection means C 85 panel requires at least a 30amp protected circuit feeding the panel C 95 panel requires at least a 40 amp protected circuit f...

Page 8: ...n the ON position 2 If the GFCI tests okay restore power by pushing the RESET button back in THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND REMAINS DEPRESSED AFTER PRES...

Page 9: ...ippers to the outer ring position for the entire period that the aerator is to be turned ON i e 15min for each tripper on the 24 hour dial When the tripper is pushed to the inside the switch is in the...

Page 10: ...50 5A Prop 2400VFX 1 240595 5B Prop 3400VFX 3400HVFX 1 340595 5C Prop 4400VFX 4400HVFX 1 440600 6A Top disk 2400VFX 1 241025 6B Top disk 3400VFX 3400HVFX 1 241035 6C Top disk 4400VFX 4400HVFX 1 241045...

Page 11: ...unit upside down if it will sit for a long period of time to ensure continued oil lubrication of seals units that sit upright for many months or years have a greater likelihood of seals drying out CLE...

Page 12: ...riginal receipt and registering the equipment online at kascomarine com under the Warranty Information section Once warranty coverage has been established the unit may be sent to Kasco Marine or any K...

Page 13: ...t before the work is performed All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer Rejected equipment can be returned at the customer s expense for s...

Page 14: ...aker single phase units only Each Kasco aerator has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will start back up If you are noticing th...

Page 15: ...customer to ship and pay freight to Kasco Note Contact Information should be that of the person or company to contact for repair information Company name Contact name First name Last name Address Str...