Possible cause
Battery voltage too low
Connector contacts and connections faulty
12 V switch on fridge off
Fuse in the fuse box defective
Fridge or cabling faulty
Relay in charging device faulty
Bad electrical contacts (too loose)
Earth leakage circuit breaker has been
triggered
Remedy
Charge body battery, start motor and allow
to run for approx. 30 seconds.
Battery voltage rises over 12 V and charging
starts.
Check and correct fault if necessary
Set switch A to 12 V position (Page 6-8)
Replace fuse (Page 7-4)
Contact specialist workshop
Contact specialist workshop
Replace charger
Check and correct fault if necessary
Switch on the circuit breaker again after
error inspection (p. 7-5).
Defect
Body battery does not charge when
connected to 230 V network
12 V operation of fridge not possible during
travel
230 V operation of fridge not possible
Power supply
FAULT IDENTIFICATION AND CORRECTION
11-5