Possible cause
Cutout triggered
Body battery is too weak or faulty
Body battery is too weak or faulty
Temperature in boiler environment under 3°C
Body battery is too weak or faulty
Frost protection valve faulty
Water pressure too high
Hot air heat exchanger blocked
Gas pressure regulator iced up
Proportion of butane in gas cylinder too high
Remedy
Contact specialist workshop
Charge or change battery
Close valve by hand and charge or change
battery
Warm up body (the valve can only be
closed at 8°C)
Charge or change battery
Contact specialist workshop
Check pump pressure, max. 2.8 bar
Check the exit opening
Use a deicer
Use propane
Defect
"Operating" (green) lamp at the Trumatic
device is not illuminated.
"Operating" (green) lamp at the Trumatic
device is not illuminated.
Frost protection valve has opened and
emptied the boiler
Frost protection valve cannot be closed.
Water drips from safety/ discharge valve
Heating switches to fault mode after longer
operating time
Heating/ hot water
FAULT IDENTIFICATION AND CORRECTION
11-3