GAS INSTALLATION
6-4
D = Red pilot light "Fault"
Indicates a fault in the gas or mains input.
In such a case consult the fault table
(see p. 11-2) or the attached operating
instructions of the combination unit.
E = Yellow pilot light "Boiler heat-up phase"
Lights up during the heating-up phase
of the boiler. When the water or air
temperature set has been reached the
light goes off.
Start-up of the heating and boiler:
1. Switch on mains input on the control panel
(p. 6-1).
2. Open main valve on gas cylinder and
shut-off valve (p. 5-2).
3. Set desired temperature stage at knob A.
4. Set knob C to desired mode of operation.
Switching off after extended shutdown:
1. Bring knob C to the middle position.
2. Drain boiler.
3. Close gas valves.
Note
Note also the attached original operating
instructions.
- with the switch at
Down 2
, the hot air fan
of the heating switches off and the content
of the boiler is heated up to 60°C at the
lowest burner stage.
Control element and modes of operation
A = Knob for room temperature
When the device is switched on, the green
lamp (B) of the knob should be illuminated.
If the light does not light up, check the
cutout III on the control panel (p. 6-1).
C = Knob with five positions
- Up = Boiler (summer mode, temperature
60°C or 40°C)
- Middle = Off
- Down 1 = H Boiler (winter mode,
without hot water requirement)
- Down 2 = H Boiler (winter mode,
with hot water requirements, 60°C)
A
E
D
B
C
Up
Middle
Down 1
Down 2
Trumatic heater
The Trumatic heating system in your Karmann-
Mobil motorhome is equipped in addition with
an integrated 12 ltr. boiler to supply the bathroom
and the kitchen with hot water. The control
element is mounted above the superstructure
door. The warmed heating air is distributed
throughout the living room by means of a
circulation fan.
In
summer mode
(water heating without room
heating) the service water is heated up on
the lowest burner stage. Once the water
temperature set has been reached, the burner
switches off. The yellow lamp (E) goes out.
In
winter mode
the unit determines automatically
through the thermostat which burner stage is
needed.
Once the desired temperature has been
reached:
- with the switch at
Down 1
, the heating
switches off regardless of the water
temperature, and with the boiler full the
water is automatically also heated, or
Heating and hot water supply
Location:
In the wardrobe.