32
English
1. Check the oil level at the sight glass and refill with oil if
necessary (to the middle of the sight glass).
Oil type 15W-40.
2. Unscrew the cap from the oil filler opening.
3. Refill with oil.
4. Screw the cap onto the oil filler opening.
5. Wipe off any overflowed oil.
17
Troubleshooting guide
You can remedy minor faults using the following overview.
If in any doubt, please contact your authorised Customer
Service.
DANGER
Risk of injury
Switch off the carrier vehicle before carrying out any care
and maintenance work.
DANGER
Risk of electric shock
Disconnect the plus terminal of the battery before carrying
out any care and maintenance work.
ATTENTION
Repair work and work on electrical components must only
be performed by your authorised Customer Service.
Malfunction
Cause
Remedy
Battery malfunction indi-
cator lights up
●
Battery is not charging
Contact Customer Service
System care container
warning light lights up
●
Container empty
Note
The burner switches off
Refill with RM 110 system care liquid
The burner does not start
up
●
Fuel canister empty
Refill Diesel
●
Blower switch switched off
Switch on the blower switch
Burner emitting sooty
smoke
●
Burner incorrectly adjusted or dirty
Contact Customer Service
●
Fuel solenoid valve defective
Note
Diesel fuel continues dripping
Contact Customer Service
White smoke emitted from
the burner
●
No ignition spark present (visible
through the sight glass in the burner
cover)
Contact Customer Service
●
Condensation in the nozzle carrier
Contact Customer Service
●
Fuel pressure too low
Contact Customer Service
Working pressure fluctu-
ates
Leaks in the high-pressure pump suc-
tion area
1. Check the piping system
Water filter dirty
1. Clean/replace the water filter
High-pressure pump not
building up pressure
Nozzle clogged/washed out
1. Clean/replace the nozzle
Supply line to high-pressure pump
leaking or clogged
1. Have this checked by Customer Service
Safety valve leaking
1. Have the setting and seals checked by Customer
Service
High-pressure pump
knocking
Supply lines to high-pressure pump
leaking
1. Check and contact Customer Service if neces-
sary
Water dripping out of the
casing
High-pressure pump leaking
1. Check, 3 drops of water per minute are normal
In case of more serious leaks, have the device
checked by Customer Service
Overflow valve continu-
ously opening/closing
(when the trigger gun is
open)
Nozzle clogged
1. Clean the nozzle
Overflow valve incorrectly adjusted/
defective
1. Have the overflow valve adjusted/replaced by
Customer Service
Device is scaled
1. Contact Customer Service